COVID-19: Open for business - Click for more info.

FREE DELIVERY ON ORDERS OVER £150,
WITH NEXT-DAY OPTIONS ALSO AVAILABLE

Seaward Primetest 250+ PAT Tester Pro Bundle

  • Produce hard copies on site with the TNT Pro Printer
  • 110V appliance adaptor for testing power tools
  • PrimeTest checkbox included to help ensure accuracy

£859.00 EXC. VAT

IN STOCK

Description

The Primetest 250+ PAT Tester is the latest offering from the market leaders Seaward. The device provides a lightweight yet powerful portable appliance testing solution. The 250 Plus has a comprehensive range of electrical tests and has been designed to perform them quickly and efficiently to save the user time.

The tester is uniquely placed in the market with it being fully compliant to the most current recommendations outlined in the IEE code of practice 4th Edition. Users will benefit from its ergonomic construction with all function buttons clearly labelled and within reach.  The functionality continues as the device has an internal memory ideal for storing and downloading up to 999 test results perfect when being used in conjunction with the Seaward Pro Printer.

Test procedures include insulation tests at 250V and 500V, protective conductor tests, touch current, 3 phase leakage current (please see the Seaward TPA 3 Phase Adaptors), RCD (30mA/150mA), low current continuity tests, IEC lead tests and power socket tests.

Seaward Primetest 250+ Main Features

  • Portable battery powered device – Designed for ease of use with clearly mapped functions
  • Ergonomic Design – Fits within one hand for fast use
  • Comprehensive range of test procedures 
  • Internal Memory – Capable of storing and downloading 999 test results 
  • Seaward Elements Software Included
  • Single button save key and download
  • All results time stamped for full traceability
  • Tests 3 Phase Appliances
  • Plug and Play printing - Compatible with Seaward Pro Printer no setup required
  • Patent-pending low current earth continuity tests guarantees accurate measurements

Seaward Primetest 250 Plus PAT Tester Pro Bundle Includes:

  • Seaward Primetest 250+ PAT Tester accessories
  • Seaward Test n' Tag Pro Printer (Serial version)
  • 110V Appliance Adaptor
  • Cloverleaf Adaptor
  • PrimeTest Checkbox
  • Seaward PAT Training Online Course Voucher
  • PATBag Carry Case

For more information on the Seaward Primetest 250 Plus please click here.

  Elements Bundle Pro Bundle Pro Bundle with Software 3-Phase Kit
Seaward Primetest 250+ PAT Tester accessories
110V Appliance Adaptor
Clover Leaf Adaptor
IEC Adaptor Kit
Primetest Checkbox
Seaward PAT Training Online Course Voucher
Seaward PATBag Carry Case

Seaward Test n' Tag Pro Printer (Serial version)

SimplyPATs Version 7 Manual Software  
Seaward PATGuard Elite 3 Software
(1 Year Licence)
 
16A three-phase adaptor
32A three-phase adaptor

Specification

Earth Continuity

  • Output Current - 200mA minimum into 2Ω
  • Test Voltage (o/c) - 9V DC nominal
  • Test Duration (Class I Test) - 2s nominal
  • Display Range - 0.01Ω to 19.99Ω
  • Pass Value (Class I Test) - 0.2Ω

Insulation Resistance

  • Test Voltage - 250/500V DC @1mA nominal, <2mA (s/c)
  • Test Duration (Class I or II) - 2s
  • Display Range - 0.01MΩ to 19.99MΩ
  • Pass Value - Class I: 1.0MΩ, Class II: 2.0MΩ

Equivalent Leakage

  • Test Voltage - 40V Nominal AC 50Hz Open Circuit
  • Test Duration - 2s
  • Display Range - 0.1mA to 19.99mA
  • Pass Value - 0.75mA/3.5mA (user selectable with 0.75mA as default)/0.25mA CL II

IEC Lead Test

  • Test Voltage - 5V DC Nominal
  • Test Duration - Time for Test (2s max)
  • Test - Live/Neutral Checks for o/c, s/c and crossed

Protective Conductor Current

  • Test Voltage - Supply voltage, max current 13A
  • Test Duration - 120s Maximum
  • Display Range - 0.15mA to 9.99mA
  • Pass Value - 0.75mA/3.5mA (user selectable with 0.75mA as default) 

Touch Current

  • Test Voltage - Supply voltage, max current 13A
  • Test Duration - 120s maximum
  • Display Range - 0.10mA to 3.50mA
  • Pass Value - 0.25mA

3 Phase Differential Leakage Current *Requires 3 phase adaptor accessory

  • Test Voltage - 3 phase supply voltage
  • Test Duration - Continuous measurements
  • Display Range - 0.10mA to 9.99mA
  • Pass Value - 0.75mA/3.5mA (user selectable with 0.75mA as default) 

RCD Trip Time

  • Test Voltage - Mains supply voltage
  • Test Current - 30mA/150mA rms sinusoidal
  • Test Current Phase - 0/180° auto switched on alternate tests
  • Measuring Range - 0ms to 500ms
  • Pass Value - 200ms

Power Socket Check

  • Input Voltage Range - 225-254V AC max current 13A UK
  •  Indicates configuration of voltage potentiall - Line to earth, line to neutral, neutral to earth

General

  • Memory Size - 999 Test Records
  • Power Source - 6 x AA Batteries

Supplied Accessories

The Seaward Primetest 250 Plus Pro Bundle comes with:

  • Seaward Primetest 250+ PAT Tester accessories
  • Seaward Test n' Tag Pro Printer (Serial version)
  • 110V Appliance Adaptor
  • Cloverleaf Adaptor
  • PrimeTest Checkbox
  • Seaward PAT Training Online Course Voucher
  • PATBag Carry Case

Videos

 

The Primetest 250+ PAT Tester is the latest offering from the market leaders Seaward. The device provides a lightweight yet powerful portable appliance testing solution. The 250 Plus has a comprehensive range of electrical tests and has been designed to perform them quickly and efficiently to save the user time.

The tester is uniquely placed in the market with it being fully compliant to the most current recommendations outlined in the IEE code of practice 4th Edition. Users will benefit from its ergonomic construction with all function buttons clearly labelled and within reach.  The functionality continues as the device has an internal memory ideal for storing and downloading up to 999 test results perfect when being used in conjunction with the Seaward Pro Printer.

Test procedures include insulation tests at 250V and 500V, protective conductor tests, touch current, 3 phase leakage current (please see the Seaward TPA 3 Phase Adaptors), RCD (30mA/150mA), low current continuity tests, IEC lead tests and power socket tests.

Seaward Primetest 250+ Main Features

  • Portable battery powered device – Designed for ease of use with clearly mapped functions
  • Ergonomic Design – Fits within one hand for fast use
  • Comprehensive range of test procedures 
  • Internal Memory – Capable of storing and downloading 999 test results 
  • Seaward Elements Software Included
  • Single button save key and download
  • All results time stamped for full traceability
  • Tests 3 Phase Appliances
  • Plug and Play printing - Compatible with Seaward Pro Printer no setup required
  • Patent-pending low current earth continuity tests guarantees accurate measurements

Seaward Primetest 250 Plus PAT Tester Pro Bundle Includes:

  • Seaward Primetest 250+ PAT Tester accessories
  • Seaward Test n' Tag Pro Printer (Serial version)
  • 110V Appliance Adaptor
  • Cloverleaf Adaptor
  • PrimeTest Checkbox
  • Seaward PAT Training Online Course Voucher
  • PATBag Carry Case

For more information on the Seaward Primetest 250 Plus please click here.

  Elements Bundle Pro Bundle Pro Bundle with Software 3-Phase Kit
Seaward Primetest 250+ PAT Tester accessories
110V Appliance Adaptor
Clover Leaf Adaptor
IEC Adaptor Kit
Primetest Checkbox
Seaward PAT Training Online Course Voucher
Seaward PATBag Carry Case

Seaward Test n' Tag Pro Printer (Serial version)

SimplyPATs Version 7 Manual Software  
Seaward PATGuard Elite 3 Software
(1 Year Licence)
 
16A three-phase adaptor
32A three-phase adaptor

Earth Continuity

  • Output Current - 200mA minimum into 2Ω
  • Test Voltage (o/c) - 9V DC nominal
  • Test Duration (Class I Test) - 2s nominal
  • Display Range - 0.01Ω to 19.99Ω
  • Pass Value (Class I Test) - 0.2Ω

Insulation Resistance

  • Test Voltage - 250/500V DC @1mA nominal, <2mA (s/c)
  • Test Duration (Class I or II) - 2s
  • Display Range - 0.01MΩ to 19.99MΩ
  • Pass Value - Class I: 1.0MΩ, Class II: 2.0MΩ

Equivalent Leakage

  • Test Voltage - 40V Nominal AC 50Hz Open Circuit
  • Test Duration - 2s
  • Display Range - 0.1mA to 19.99mA
  • Pass Value - 0.75mA/3.5mA (user selectable with 0.75mA as default)/0.25mA CL II

IEC Lead Test

  • Test Voltage - 5V DC Nominal
  • Test Duration - Time for Test (2s max)
  • Test - Live/Neutral Checks for o/c, s/c and crossed

Protective Conductor Current

  • Test Voltage - Supply voltage, max current 13A
  • Test Duration - 120s Maximum
  • Display Range - 0.15mA to 9.99mA
  • Pass Value - 0.75mA/3.5mA (user selectable with 0.75mA as default) 

Touch Current

  • Test Voltage - Supply voltage, max current 13A
  • Test Duration - 120s maximum
  • Display Range - 0.10mA to 3.50mA
  • Pass Value - 0.25mA

3 Phase Differential Leakage Current *Requires 3 phase adaptor accessory

  • Test Voltage - 3 phase supply voltage
  • Test Duration - Continuous measurements
  • Display Range - 0.10mA to 9.99mA
  • Pass Value - 0.75mA/3.5mA (user selectable with 0.75mA as default) 

RCD Trip Time

  • Test Voltage - Mains supply voltage
  • Test Current - 30mA/150mA rms sinusoidal
  • Test Current Phase - 0/180° auto switched on alternate tests
  • Measuring Range - 0ms to 500ms
  • Pass Value - 200ms

Power Socket Check

  • Input Voltage Range - 225-254V AC max current 13A UK
  •  Indicates configuration of voltage potentiall - Line to earth, line to neutral, neutral to earth

General

  • Memory Size - 999 Test Records
  • Power Source - 6 x AA Batteries

The Seaward Primetest 250 Plus Pro Bundle comes with:

  • Seaward Primetest 250+ PAT Tester accessories
  • Seaward Test n' Tag Pro Printer (Serial version)
  • 110V Appliance Adaptor
  • Cloverleaf Adaptor
  • PrimeTest Checkbox
  • Seaward PAT Training Online Course Voucher
  • PATBag Carry Case