Seaward Primetest 250+ PAT Tester Pro Bundle with Software
- Compact TNT Pro Printer creates hard copies on site
- Adaptors provided for 110V appliances and extension leads
- Seaward PATGuard Elite 3 software facilitates organisation and analysis
The Primetest 250+ is a lightweight battery powered downloading PAT from Seaward. The device is capable of storing up to 999 test results and is capable of a comprehensive array of tests normally only available on high specification mains powered PAT Testers.
The tester has the added benefit of being one of the only PAT Testers currently available which fully complies with the latest edition of the IEE Code of Practice. Seaward have considered the user experience by building a tester that is truly ergonomic and portable. The Primetest 250+ has test procedures clearly labelled enabling a user to perform tests easily and quickly. The major benefit of the Seaward Primetest 250 Plus is its compatibility with the Seaward Pro Printer (included in the kit) allowing a user to print all relevant test results at the push of a button.
Despite being lightweight the Primetest 250+ can perform tests normally not custom to battery powered devices including protective conductor tests, IEC lead tests, touch current, 3 phase leakage current (please see the Seaward TPA 3 Phase Adaptors) RCD (30mA/150mA) and power socket tests, low current continuity tests and even insulation tests at 250V and 500V.
This kit comes with the Seaward PATGuard Elite 3 software (with 12 months license), which is ideal for downloading your data into and creating professional reports and certificates. Seaward PATGuard 3 software also helps you manage all your PAT data and can remind you once re-testing is due. This is the ultimate software solution for managing you PAT data and Health & Safety information either as a contractor of if PAT testing is undertaken in house.
Seaward Primetest 250+ Main Features
- Portable battery powered device – Designed for ease of use with clearly mapped functions
- Ergonomic Design – Fits within one hand for fast use
- Comprehensive range of test procedures
- Internal Memory – Capable of storing and downloading 999 test results
- Seaward Elements Software Included
- Single button save key and download
- All results time stamped for full traceability
- Tests 3 Phase Appliances
- Plug and Play printing - Compatible with Seaward Pro Printer no setup required
- Patent-pending low current earth continuity tests guarantees accurate measurements
Seaward Primetest 250 Plus PAT Tester Pro Software Bundle Includes:
- Seaward Primetest 250+ PAT Tester accessories
- Seaward PATGuard Elite 3 Software - 1 Year Licence
- Seaward Test n' Tag Pro Printer (Serial version)
- 110V Appliance Adaptor
- Clover Leaf Adaptor
- Primetest Checkbox
- Seaward PAT Training Online Course Voucher
- PATBag Carry Case
For more information on the Seaward Primetest 250 Plus please click here.
Elements Bundle | Pro Bundle | Pro Bundle with Software | 3-Phase Kit | |
---|---|---|---|---|
Seaward Primetest 250+ PAT Tester accessories | ✔ | ✔ | ✔ | ✔ |
110V Appliance Adaptor | ✔ | ✔ | ✔ | ✔ |
Clover Leaf Adaptor | ✔ | ✔ | ✔ | |
IEC Adaptor Kit | ✔ | |||
Primetest Checkbox | ✔ | ✔ | ✔ | |
Seaward PAT Training Online Course Voucher | ✔ | ✔ | ✔ | |
Seaward PATBag Carry Case | ✔ | ✔ | ✔ | ✔ |
Seaward Test n' Tag Pro Printer (Serial version) |
✔ | ✔ | ||
SimplyPATs Version 7 Manual Software | ✔ | ✔ | ||
Seaward PATGuard Elite 3 Software (1 Year Licence) |
✔ | |||
16A three-phase adaptor | ✔ | |||
32A three-phase adaptor | ✔ |
Earth Continuity
- Output Current - 200mA minimum into 2Ω
- Test Voltage (o/c) - 9V DC nominal
- Test Duration (Class I Test) - 2s nominal
- Display Range - 0.01Ω to 19.99Ω
- Pass Value (Class I Test) - 0.2Ω
Insulation Resistance
- Test Voltage - 250/500V DC @1mA nominal, <2mA (s/c)
- Test Duration (Class I or II) - 2s
- Display Range - 0.01MΩ to 19.99MΩ
- Pass Value - Class I: 1.0MΩ, Class II: 2.0MΩ
Equivalent Leakage
- Test Voltage - 40V Nominal AC 50Hz Open Circuit
- Test Duration - 2s
- Display Range - 0.1mA to 19.99mA
- Pass Value - 0.75mA/3.5mA (user selectable with 0.75mA as default)/0.25mA CL II
IEC Lead Test
- Test Voltage - 5V DC Nominal
- Test Duration - Time for Test (2s max)
- Test - Live/Neutral Checks for o/c, s/c and crossed
Protective Conductor Current
- Test Voltage - Supply voltage, max current 13A
- Test Duration - 120s Maximum
- Display Range - 0.15mA to 9.99mA
- Pass Value - 0.75mA/3.5mA (user selectable with 0.75mA as default)
Touch Current
- Test Voltage - Supply voltage, max current 13A
- Test Duration - 120s maximum
- Display Range - 0.10mA to 3.50mA
- Pass Value - 0.25mA
3 Phase Differential Leakage Current *Requires 3 phase adaptor accessory
- Test Voltage - 3 phase supply voltage
- Test Duration - Continuous measurements
- Display Range - 0.10mA to 9.99mA
- Pass Value - 0.75mA/3.5mA (user selectable with 0.75mA as default)
RCD Trip Time
- Test Voltage - Mains supply voltage
- Test Current - 30mA/150mA rms sinusoidal
- Test Current Phase - 0/180° auto switched on alternate tests
- Measuring Range - 0ms to 500ms
- Pass Value - 200ms
Power Socket Check
- Input Voltage Range - 225-254V AC max current 13A UK
- Indicates configuration of voltage potentially - Line to earth, line to neutral, neutral to earth
General
- Memory Size - 999 Test Records
- Power Source - 6 x AA Batteries
- Seaward Primetest 250+ PAT Tester accessories
- Seaward PATGuard Elite 3 Software - 1 Year Licence
- Seaward Test n' Tag Pro Printer (Serial version)
- 110V Appliance Adaptor
- Clover Leaf Adaptor
- Primetest Checkbox
- Seaward PAT Training Online Course Voucher
- PATBag Carry Case