COVID-19: Open for business - Click for more info.

FREE DELIVERY ON ORDERS OVER £150,
WITH NEXT-DAY OPTIONS ALSO AVAILABLE

Martindale HPAT600/2 Kit B

  • Large carry case for tester and accessories
  • PAT Certificate Pad and PAT Register Book for keeping paper records
  • Full range of adaptors for 110V appliances and IEC leads

£429.00 EXC. VAT

IN STOCK

Description

The Martindale HPAT600/2 portable appliance tester offers improved functionality with auto test mode, data storage, dual voltage insulation test and user adjustable pass and fail limits (ideal when testing longer extension leads).

The manual mode of the HPAT600/2 tester is perfect for entry level users while the auto mode allows more experienced PAT testers to quickly select the desired test sequence and commence testing.

In addition the Martindale HPAT600/2 uses rechargeable batteries and is supplied with a mains charger and in-car charger, allowing the unit to be recharged when not in use and even when travelling between sites.

The Martindale HPAT600/2 PAT Tester is capable of storing test results for up to 200 appliances which can be quickly reviewed on the screen and used when filling out PAT certificates and log books.

Martindale HPAT600/2 PAT Tester Kit B Includes:

  • Martindale HPAT600/2 PAT Tester (complete with Earth Bond Lead & Crocodile Clip, Mains Lead, In-Car Charger, 230V Extension Lead Adaptor, HPAT600 Instruction Manual, 6 x Rechargeable Batteries and Carry Case).
  • PAT Certificate Pad
  • PAT Register Book w/ Frequency of Inspection
  • IEC Clover Leaf Adaptor
  • 110V Appliance Adaptor
  • 110V Extension Lead Adaptor
  • Martindale CP501 Socket Tester
  • 1000 Pass Labels
  • 200 Fail Labels
  • 250 PassWrap Cable Labels
  • 250 Tuff Tag Pass Cable Labels
  • Portable Appliance Tester Kit Carry Case

For more detailed information on the Martindale HPAT600/2 Portable Appliance Tester please click here.

Kit A Kit B Kit C Kit D
Martindale HPAT600/2 PAT Tester
Microwave Leakage Detector
50 Microwave Emissions Labels
PAT Certificate Pad
PAT Register Book w/ Frequency of Inspection
IEC Clover Leaf Adaptor
Martindale CP501 Check Plug
1000 Pass Labels
200 Fail Labels
250 PassWrap Cable Labels
250 Tuff Tag Cable Labels
Earth Bond Test Lead
Mains Lead
230V Extension Lead Adaptor
110V Appliance Adapter
110V Extension Lead Adaptor
Rechargeable Batteries
In-Car Charger
HandyPAT 600 Carry Case
Portable Appliance Tester Kit Carry Case

Specification

Earth Bond Test (IT Safe)

  • Test Current: 200mA DC
  • Test Voltage: 4V DC
  • Range: 0 - 19.99Ω
  • Resolution: 0.01Ω
  • Default Pass Value: 0.1Ω
  • User Selectable Pass Value: 0.1Ω to 0.9Ω in 0.1Ω steps

Insulation Resistance

  • Test Voltage: 500V: >500V DC at 1mA, 250V: >250V DC at 1mA
  • Default Pass Value: Class I - 1MΩ, Class II - 2MΩ
  • User Selectable Pass Value: 0.3MΩ to 1MΩ in 0.1Ω steps, or
  • 1MΩ to 10MΩ in 1MΩ steps

IEC & Extension Lead Test

  • Earth Continuity: 200mA DC
  • Insulation Test: 500V DC
  • Wiring Test: Live, Neutral Continuity & Polarity

Fuse Test

  • Test Voltage: 4V DC
  • Test Current: 200mA DC
  • Pass Level: >2mA

Simulated Load Test

  • Test Voltage: 4V DC
  • Test Current: 200mA DC
  • Accuracy: +/- (5% reading + 2 digits, referenced up to 230V)

Supplied Accessories

Martindale HPAT600/2 Kit B comes with:

  • Martindale HPAT600/2 PAT Tester (complete with Earth Bond Lead & Crocodile Clip, Mains Lead, In-Car Charger, 230V Extension Lead Adaptor, HPAT600 Instruction Manual, 6 x Rechargeable Batteries and Carry Case).
  • PAT Certificate Pad
  • PAT Register Book w/ Frequency of Inspection
  • IEC Clover Leaf Adaptor
  • 110V Appliance Adaptor
  • 110V Extension Lead Adaptor
  • Martindale CP501 Socket Tester
  • 1000 Pass Labels
  • 200 Fail Labels
  • 250 PassWrap Cable Labels
  • 250 Tuff Tag Pass Cable Labels
  • Portable Appliance Tester Kit Carry Case

 

The Martindale HPAT600/2 portable appliance tester offers improved functionality with auto test mode, data storage, dual voltage insulation test and user adjustable pass and fail limits (ideal when testing longer extension leads).

The manual mode of the HPAT600/2 tester is perfect for entry level users while the auto mode allows more experienced PAT testers to quickly select the desired test sequence and commence testing.

In addition the Martindale HPAT600/2 uses rechargeable batteries and is supplied with a mains charger and in-car charger, allowing the unit to be recharged when not in use and even when travelling between sites.

The Martindale HPAT600/2 PAT Tester is capable of storing test results for up to 200 appliances which can be quickly reviewed on the screen and used when filling out PAT certificates and log books.

Martindale HPAT600/2 PAT Tester Kit B Includes:

  • Martindale HPAT600/2 PAT Tester (complete with Earth Bond Lead & Crocodile Clip, Mains Lead, In-Car Charger, 230V Extension Lead Adaptor, HPAT600 Instruction Manual, 6 x Rechargeable Batteries and Carry Case).
  • PAT Certificate Pad
  • PAT Register Book w/ Frequency of Inspection
  • IEC Clover Leaf Adaptor
  • 110V Appliance Adaptor
  • 110V Extension Lead Adaptor
  • Martindale CP501 Socket Tester
  • 1000 Pass Labels
  • 200 Fail Labels
  • 250 PassWrap Cable Labels
  • 250 Tuff Tag Pass Cable Labels
  • Portable Appliance Tester Kit Carry Case

For more detailed information on the Martindale HPAT600/2 Portable Appliance Tester please click here.

Kit A Kit B Kit C Kit D
Martindale HPAT600/2 PAT Tester
Microwave Leakage Detector
50 Microwave Emissions Labels
PAT Certificate Pad
PAT Register Book w/ Frequency of Inspection
IEC Clover Leaf Adaptor
Martindale CP501 Check Plug
1000 Pass Labels
200 Fail Labels
250 PassWrap Cable Labels
250 Tuff Tag Cable Labels
Earth Bond Test Lead
Mains Lead
230V Extension Lead Adaptor
110V Appliance Adapter
110V Extension Lead Adaptor
Rechargeable Batteries
In-Car Charger
HandyPAT 600 Carry Case
Portable Appliance Tester Kit Carry Case

Earth Bond Test (IT Safe)

  • Test Current: 200mA DC
  • Test Voltage: 4V DC
  • Range: 0 - 19.99Ω
  • Resolution: 0.01Ω
  • Default Pass Value: 0.1Ω
  • User Selectable Pass Value: 0.1Ω to 0.9Ω in 0.1Ω steps

Insulation Resistance

  • Test Voltage: 500V: >500V DC at 1mA, 250V: >250V DC at 1mA
  • Default Pass Value: Class I - 1MΩ, Class II - 2MΩ
  • User Selectable Pass Value: 0.3MΩ to 1MΩ in 0.1Ω steps, or
  • 1MΩ to 10MΩ in 1MΩ steps

IEC & Extension Lead Test

  • Earth Continuity: 200mA DC
  • Insulation Test: 500V DC
  • Wiring Test: Live, Neutral Continuity & Polarity

Fuse Test

  • Test Voltage: 4V DC
  • Test Current: 200mA DC
  • Pass Level: >2mA

Simulated Load Test

  • Test Voltage: 4V DC
  • Test Current: 200mA DC
  • Accuracy: +/- (5% reading + 2 digits, referenced up to 230V)

Martindale HPAT600/2 Kit B comes with:

  • Martindale HPAT600/2 PAT Tester (complete with Earth Bond Lead & Crocodile Clip, Mains Lead, In-Car Charger, 230V Extension Lead Adaptor, HPAT600 Instruction Manual, 6 x Rechargeable Batteries and Carry Case).
  • PAT Certificate Pad
  • PAT Register Book w/ Frequency of Inspection
  • IEC Clover Leaf Adaptor
  • 110V Appliance Adaptor
  • 110V Extension Lead Adaptor
  • Martindale CP501 Socket Tester
  • 1000 Pass Labels
  • 200 Fail Labels
  • 250 PassWrap Cable Labels
  • 250 Tuff Tag Pass Cable Labels
  • Portable Appliance Tester Kit Carry Case