COVID-19: Open for business - Click for more info.

FREE DELIVERY ON ORDERS OVER £150,
WITH NEXT-DAY OPTIONS ALSO AVAILABLE

Kewtech EZYPAT Kit B

  • PAT tester capable of regular automatic test sequences on appliances and leads
  • Adaptors included for 110V appliances, 110V extension leads and IEC leads
  • Full set of indoor and outdoor PAT labels with certificate pad and register book

£429.00 EXC. VAT

IN STOCK

Description

Kewtech EZYPAT Kit B is an excellent solution for low-volume appliance testing in commercial and industrial settings. The Kewtech EZYPAT PAT Tester is an entry-level tester capable of performing earth bond, insulation, polarity and substitute leakage tests. It has automatic test sequences for Class I appliances, Class II appliances and extension/IEC leads. The tester is operated using simple push buttons and results are clearly displayed alongside a PASS/FAIL indication on screen.

Various accessories in Kewtech EZYPAT Kit B help facilitate an easier testing process over a greater range of appliances. There are 110V adaptors for both appliances and extension leads - thus enabling testing on construction equipment - and an IEC adaptor set for testing leads and power cords used for IT equipment. Outdoor PASS labels are included for outdoor equipment alongside regular PAT labels and there are also a certificate pad, register book socket tester and carry case.

For more information on the Kewtech EZYPAT PAT Tester, please click here.

Kit Contents

  • Kewtech EZYPAT PAT Tester
  • Two rolls of PASS labels (x500)
  • Fail labels (x200)
  • PassWrap labels (x250)
  • Tuff Tag Pass labels (x250)
  • PAT certificate pad
  • PAT register book
  • IEC adaptor kit
  • 110V appliance adaptor
  • 110V extension lead adaptor
  • Kewtech KT103 Socket Tester
  • Kewtech carry case

  Kit A Kit B Kit C
Kewtech EZYPAT PAT Tester
PASS labels x2 x2 x2
FAIL labels
PassWrap labels
Tuff Tag Pass Labels  
PAT certificate pad
PAT registerbook x1 x1 x2
IEC clover leaf adaptor    
IEC adaptor kit  
110V appliance adaptor  
110V extension lead adaptor  
Kewtech KT103 Socket Tester
Microwave leakage detector
Microwave emission labels
Kewtech KITBAG2 carry case

Specification

Protective Conductor Resistance

  • Measuring range: 0.00 - 20.00 Ω (NULL value inc)*
  • Over-range indication: > 20.00 Ω
  • Resolution: 0.01Ω
  • Open-circuit voltage: 5 V ±0.4 V DC
  • Measuring current: 200 mA DC (nominal value)
  • Accuracy: ±3%rdg ±5dgt

Insulation

  • Rated voltage: 250V / 500V
  • Measuring range: 0.00 - 20.00 MΩ
  • Over-range indication: > 20.00 MΩ
  • Resolution: 0.01 MΩ
  • No-load voltage: 250 V DC +20%, -0% / 500 V DC +20%, -0%
  • Short-circuit current: 1.5 mA DC or less
  • Rated current: 1 -1.2 mA with a load of 0.25 MΩ / 1 to 1.2 mA with a load of 0.5 MΩ
  • Accuracy: ±2%rdg±3dgt

Substitute Leakage

  • Measuring range: 0.10 - 12.00 mA rms
  • Over-range indication: > 12.00 mA
  • Resolution: 0.01mA
  • Open-circuit voltage/ Freq.: 30 V ±5 V rms / 50 Hz ±5%
  • Measuring current: 1.2 mA AC ±0.5 mA (when measuring 12.00 mA)
  • Accuracy: ±3%rdg±5dgt

Applicable Standards

  • Safety: IEC/EN61010-1 CAT II 300V-instrument; IEC/EN61010-2-030; IEC/EN61010-031 CAT III 600V
  • EMC: EN61326-1, 2-2
  • Possible number of measurements where battery voltage is within the effective range (measuring every 30 sec): Approx. 1400 times (CLI Rpe: 0 Ω, Rins: 1.1 MΩ)

Supplied Accessories

  • Kewtech EZYPAT PAT Tester
  • Two rolls of PASS labels (x500)
  • Fail labels (x200)
  • PassWrap labels (x250)
  • Tuff Tag Pass labels (x250)
  • PAT certificate pad
  • PAT register book
  • IEC adaptor kit
  • 110V appliance adaptor
  • 110V extension lead adaptor
  • Kewtech KT103 Socket Tester
  • Kewtech carry case

Kewtech EZYPAT Kit B is an excellent solution for low-volume appliance testing in commercial and industrial settings. The Kewtech EZYPAT PAT Tester is an entry-level tester capable of performing earth bond, insulation, polarity and substitute leakage tests. It has automatic test sequences for Class I appliances, Class II appliances and extension/IEC leads. The tester is operated using simple push buttons and results are clearly displayed alongside a PASS/FAIL indication on screen.

Various accessories in Kewtech EZYPAT Kit B help facilitate an easier testing process over a greater range of appliances. There are 110V adaptors for both appliances and extension leads - thus enabling testing on construction equipment - and an IEC adaptor set for testing leads and power cords used for IT equipment. Outdoor PASS labels are included for outdoor equipment alongside regular PAT labels and there are also a certificate pad, register book socket tester and carry case.

For more information on the Kewtech EZYPAT PAT Tester, please click here.

Kit Contents

  • Kewtech EZYPAT PAT Tester
  • Two rolls of PASS labels (x500)
  • Fail labels (x200)
  • PassWrap labels (x250)
  • Tuff Tag Pass labels (x250)
  • PAT certificate pad
  • PAT register book
  • IEC adaptor kit
  • 110V appliance adaptor
  • 110V extension lead adaptor
  • Kewtech KT103 Socket Tester
  • Kewtech carry case

  Kit A Kit B Kit C
Kewtech EZYPAT PAT Tester
PASS labels x2 x2 x2
FAIL labels
PassWrap labels
Tuff Tag Pass Labels  
PAT certificate pad
PAT registerbook x1 x1 x2
IEC clover leaf adaptor    
IEC adaptor kit  
110V appliance adaptor  
110V extension lead adaptor  
Kewtech KT103 Socket Tester
Microwave leakage detector
Microwave emission labels
Kewtech KITBAG2 carry case

Protective Conductor Resistance

  • Measuring range: 0.00 - 20.00 Ω (NULL value inc)*
  • Over-range indication: > 20.00 Ω
  • Resolution: 0.01Ω
  • Open-circuit voltage: 5 V ±0.4 V DC
  • Measuring current: 200 mA DC (nominal value)
  • Accuracy: ±3%rdg ±5dgt

Insulation

  • Rated voltage: 250V / 500V
  • Measuring range: 0.00 - 20.00 MΩ
  • Over-range indication: > 20.00 MΩ
  • Resolution: 0.01 MΩ
  • No-load voltage: 250 V DC +20%, -0% / 500 V DC +20%, -0%
  • Short-circuit current: 1.5 mA DC or less
  • Rated current: 1 -1.2 mA with a load of 0.25 MΩ / 1 to 1.2 mA with a load of 0.5 MΩ
  • Accuracy: ±2%rdg±3dgt

Substitute Leakage

  • Measuring range: 0.10 - 12.00 mA rms
  • Over-range indication: > 12.00 mA
  • Resolution: 0.01mA
  • Open-circuit voltage/ Freq.: 30 V ±5 V rms / 50 Hz ±5%
  • Measuring current: 1.2 mA AC ±0.5 mA (when measuring 12.00 mA)
  • Accuracy: ±3%rdg±5dgt

Applicable Standards

  • Safety: IEC/EN61010-1 CAT II 300V-instrument; IEC/EN61010-2-030; IEC/EN61010-031 CAT III 600V
  • EMC: EN61326-1, 2-2
  • Possible number of measurements where battery voltage is within the effective range (measuring every 30 sec): Approx. 1400 times (CLI Rpe: 0 Ω, Rins: 1.1 MΩ)
  • Kewtech EZYPAT PAT Tester
  • Two rolls of PASS labels (x500)
  • Fail labels (x200)
  • PassWrap labels (x250)
  • Tuff Tag Pass labels (x250)
  • PAT certificate pad
  • PAT register book
  • IEC adaptor kit
  • 110V appliance adaptor
  • 110V extension lead adaptor
  • Kewtech KT103 Socket Tester
  • Kewtech carry case