COVID-19: Open for business - Click for more info.

FREE DELIVERY ON ORDERS OVER £150,
WITH NEXT-DAY OPTIONS ALSO AVAILABLE

Megger PAT420 Kit 1

  • Capable of 230V and 110V PAT testing
  • Large internal memory with room for 10,000 results
  • Barcode scanner and label printer for identification of appliances

£1,499.00 EXC. VAT

IN STOCK

Description

The Megger PAT420 Portable Appliance Tester provides earth bond testing at all three currents (200mA, 10A and 25A) as well as offering 230V and 110V operation, making the PAT420 ideal for full-time industrial or commercial users.

The Megger PAT420 PAT Tester improves productivity of testing without compromising on quality or accuracy. Direct access test buttons and a QWERTY keyboard ensure straightforward operation and rapid data entry, while manual/auto testing modes offer extended control over Pass and Fail limits.

Complete with a vast onboard memory that can store up to 10,000 records with download functionality; the Megger 420 PAT Tester is a popular choice for electrical contractors looking to perform efficient, high volume appliance testing.

Megger PAT420 PAT Testing Kit 1 (with Printer and Scanner) Includes:

  • Megger PAT420 Tester (complete with Earth Bond Test Lead & Crocodile Clip, 230V Extension Lead Adaptor, IEC Adaptor Kit less IEC Clover, PAT420 Instruction Manual, Calibration Certificate and Carry Case).
  • PAT400 Barcode Label Printer
  • 2x Printer Cartridges
  • PAT400 Barcode Scanner
  • Microwave Leakage Detector
  • 50 Microwave Emission Labels
  • 500 Pass Labels
  • 200 Fail Labels
  • 110V Extension Lead Adaptor

For more information on the Megger PAT420 PAT Tester please click here.

  Kit 1 Kit 2 Kit 3 Industrial Kit
Megger PAT420 Tester
SimplyPATs V7 Software
PAT400 Barcode Label Printer
2x Printer Cartridges
PAT400 Barcode Scanner
Microwave Leakage Detector
50 Microwave Emission Labels
Pass Labels 500 1000 1000
Fail Labels 200 400 400
PassWrap Labels 250 250
110V Extension Lead Adaptor
IEC Adaptor Kit less IEC Clover
110V Adaptor Set
230V Adaptor Set
415V 4-Pin Adaptor Set
415V 5-Pin Adaptor Set
Earth Bond Test Lead
230V Extension Lead Adaptor
Calibration Certificate
PAT420 Carry Case

Specification

Earth Bond test (10A and 25A)

  • Open circuit voltage: 9V AC (Supply 230V)
  • Resistance accuracy: ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits 0.5 to .99 Ω)
  • Resistance resolution: 10 mΩ (0 to 1.99 Ω)
  • Display range: 0 to 1.99 Ω

Continuity test (200mA)

  • Voltage: 4V DC
  • Resistance accuracy: ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits 0.5 to .99 Ω)
  • Resistance resolution: 10 mΩ (1 to 19.99 Ω)
  • Display range: 0 to 19.99 Ω

Insulation test (250/500V)

  • Resistance accuracy: ±2% ±5 digits (0 to 19.99 MΩ), ±5% ±10 digits (20 to 99.99 MΩ)
  • Resistance resolution: 0.01 MΩ
  • Display range: 0 to 99.99 MΩ

Substitute leakage test

  • Voltage: 40V AC nominal mains frequency
  • Current accuracy: ±5% ±5 digits
  • Current resolution: 0.01mA
  • Display range: 0 to 19.99mA

Differential leakage test

  • Voltage: Nominal mains supply
  • Current accuracy: ±5% ±5 digits
  • Current resolution: 0.01mA
  • Display range: 0 to 19.99mA

Touch current test

  • Voltage: Nominal mains supply
  • Current accuracy: ±5% ±5 digits
  • Current resolution: 0.01mA
  • Display range: 0 to 10mA

Operational test

  • Voltage: Nominal mains supply
  • VA accuracy: ±5% ±10 digits (0 - 99 VA), ±5% ±50 digits (100 VA - 999 VA), ±5% ±100 digits (1000 VA - 3700 VA)
  • Resolution: 1 VA (0 to 3700 VA)
  • Display range: 0 to 3999 VA

Extension lead test

  • Tests performed: Bond, insulation and polarity
  • Polarity test voltage: 12V
  • Polarity checks: Lead OK, Live neutral S/C, Live neutral reversed, Live/neutral O/C

Portable RCD test

  • Voltage: Nominal mains supply
  • Current accuracy: -8% to -2% (1/2 x I), +2% to +8% (1 x I, 5 x I)
  • Trip time accuracy: ±1% ±5 digits
  • Trip time resolution: 0.1ms
  • Display range: 0 to 1999 ms (1/2 x I), 0 to 300 ms (1 x I), 0 to 40 ms (5 x I)

Fuse test

  • Voltage: 3.3V
  • Warning: Audible bleep if fuse is OK
  • Supply range: 230V at 50Hz, 110V at 50Hz
  • Compliance: IEC 61010-1, CAT II 300V, IEC 61326-1, 61326-2-2
  • Dimensions: 180 x 255 x 320mm
  • Weight: 4.4kg

Supplied Accessories

Megger PAT420 Kit 1 comes with:

  • Megger PAT420 Tester (complete with Earth Bond Test Lead & Crocodile Clip, 230V Extension Lead Adaptor, IEC Adaptor Kit less IEC Clover, PAT420 Instruction Manual, Calibration Certificate and Carry Case).
  • PAT400 Barcode Label Printer
  • 2x Printer Cartridges
  • PAT400 Barcode Scanner
  • Microwave Leakage Detector
  • 50 Microwave Emission Labels
  • 500 Pass Labels
  • 200 Fail Labels
  • 110V Extension Lead Adaptor

Videos

The Megger PAT420 Portable Appliance Tester provides earth bond testing at all three currents (200mA, 10A and 25A) as well as offering 230V and 110V operation, making the PAT420 ideal for full-time industrial or commercial users.

The Megger PAT420 PAT Tester improves productivity of testing without compromising on quality or accuracy. Direct access test buttons and a QWERTY keyboard ensure straightforward operation and rapid data entry, while manual/auto testing modes offer extended control over Pass and Fail limits.

Complete with a vast onboard memory that can store up to 10,000 records with download functionality; the Megger 420 PAT Tester is a popular choice for electrical contractors looking to perform efficient, high volume appliance testing.

Megger PAT420 PAT Testing Kit 1 (with Printer and Scanner) Includes:

  • Megger PAT420 Tester (complete with Earth Bond Test Lead & Crocodile Clip, 230V Extension Lead Adaptor, IEC Adaptor Kit less IEC Clover, PAT420 Instruction Manual, Calibration Certificate and Carry Case).
  • PAT400 Barcode Label Printer
  • 2x Printer Cartridges
  • PAT400 Barcode Scanner
  • Microwave Leakage Detector
  • 50 Microwave Emission Labels
  • 500 Pass Labels
  • 200 Fail Labels
  • 110V Extension Lead Adaptor

For more information on the Megger PAT420 PAT Tester please click here.

  Kit 1 Kit 2 Kit 3 Industrial Kit
Megger PAT420 Tester
SimplyPATs V7 Software
PAT400 Barcode Label Printer
2x Printer Cartridges
PAT400 Barcode Scanner
Microwave Leakage Detector
50 Microwave Emission Labels
Pass Labels 500 1000 1000
Fail Labels 200 400 400
PassWrap Labels 250 250
110V Extension Lead Adaptor
IEC Adaptor Kit less IEC Clover
110V Adaptor Set
230V Adaptor Set
415V 4-Pin Adaptor Set
415V 5-Pin Adaptor Set
Earth Bond Test Lead
230V Extension Lead Adaptor
Calibration Certificate
PAT420 Carry Case

Earth Bond test (10A and 25A)

  • Open circuit voltage: 9V AC (Supply 230V)
  • Resistance accuracy: ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits 0.5 to .99 Ω)
  • Resistance resolution: 10 mΩ (0 to 1.99 Ω)
  • Display range: 0 to 1.99 Ω

Continuity test (200mA)

  • Voltage: 4V DC
  • Resistance accuracy: ±5% ±3 digits (0 to 0.49 Ω), ±5% ±5 digits 0.5 to .99 Ω)
  • Resistance resolution: 10 mΩ (1 to 19.99 Ω)
  • Display range: 0 to 19.99 Ω

Insulation test (250/500V)

  • Resistance accuracy: ±2% ±5 digits (0 to 19.99 MΩ), ±5% ±10 digits (20 to 99.99 MΩ)
  • Resistance resolution: 0.01 MΩ
  • Display range: 0 to 99.99 MΩ

Substitute leakage test

  • Voltage: 40V AC nominal mains frequency
  • Current accuracy: ±5% ±5 digits
  • Current resolution: 0.01mA
  • Display range: 0 to 19.99mA

Differential leakage test

  • Voltage: Nominal mains supply
  • Current accuracy: ±5% ±5 digits
  • Current resolution: 0.01mA
  • Display range: 0 to 19.99mA

Touch current test

  • Voltage: Nominal mains supply
  • Current accuracy: ±5% ±5 digits
  • Current resolution: 0.01mA
  • Display range: 0 to 10mA

Operational test

  • Voltage: Nominal mains supply
  • VA accuracy: ±5% ±10 digits (0 - 99 VA), ±5% ±50 digits (100 VA - 999 VA), ±5% ±100 digits (1000 VA - 3700 VA)
  • Resolution: 1 VA (0 to 3700 VA)
  • Display range: 0 to 3999 VA

Extension lead test

  • Tests performed: Bond, insulation and polarity
  • Polarity test voltage: 12V
  • Polarity checks: Lead OK, Live neutral S/C, Live neutral reversed, Live/neutral O/C

Portable RCD test

  • Voltage: Nominal mains supply
  • Current accuracy: -8% to -2% (1/2 x I), +2% to +8% (1 x I, 5 x I)
  • Trip time accuracy: ±1% ±5 digits
  • Trip time resolution: 0.1ms
  • Display range: 0 to 1999 ms (1/2 x I), 0 to 300 ms (1 x I), 0 to 40 ms (5 x I)

Fuse test

  • Voltage: 3.3V
  • Warning: Audible bleep if fuse is OK
  • Supply range: 230V at 50Hz, 110V at 50Hz
  • Compliance: IEC 61010-1, CAT II 300V, IEC 61326-1, 61326-2-2
  • Dimensions: 180 x 255 x 320mm
  • Weight: 4.4kg

Megger PAT420 Kit 1 comes with:

  • Megger PAT420 Tester (complete with Earth Bond Test Lead & Crocodile Clip, 230V Extension Lead Adaptor, IEC Adaptor Kit less IEC Clover, PAT420 Instruction Manual, Calibration Certificate and Carry Case).
  • PAT400 Barcode Label Printer
  • 2x Printer Cartridges
  • PAT400 Barcode Scanner
  • Microwave Leakage Detector
  • 50 Microwave Emission Labels
  • 500 Pass Labels
  • 200 Fail Labels
  • 110V Extension Lead Adaptor