COVID-19: Open for business - Click for more info.

FREE DELIVERY ON ORDERS OVER £150,
WITH NEXT-DAY OPTIONS ALSO AVAILABLE

Martindale HPAT400 Kit C

  • Martindale HPAT400 for testing Class I and Class II appliances and power leads
  • SimplyPATs V7 Manual Software allows user to manage testing and produce certification
  • Full set of PAT labels, extension lead adaptor, AV/IT lead adaptors, socket tester

£369.00 EXC. VAT

IN STOCK

Description

Please note that there may be delays on delivery of this product. For more information please 0113 248 9966.

Martindale HPAT400 PAT Test Kit C allows the user to test appliances and leads in residential and office premises and then carry out reporting and certification with a useful software package.

The Martindale HPAT400 PAC Checker has automatic test sequences for Class I appliances, Class II appliances and power leads. Once the test is correctly connected, all the user needs to do is press the appropriate button to initiate the test. A PASS/FAIL indication is provided for each test in the sequence alongside an overall indication. This means that the HPAT400 is unsuitable for long extension leads. Tests include earth bond, insulation resistance, leakage current and polarity checking.

Martindale HPAT400 Kit C includes SimplyPATs V7 Manual Software. This useful software package allows the user to keep track of data, customer information, and test sites as well as producing invoices and certification as required. Other accessories in Kit C include adaptors, PAT labels and a socket tester.

Martindale HPAT400 Kit C Includes:

  • Martindale HPAT400 PAC Checker
  • SimplyPATs Version 7 Manual PAT Software
  • PAT Register Book w/ Frequency of Inspection
  • IEC Clover Leaf Adaptor
  • Martindale CP501 Socket Tester
  • 1000 Pass Labels
  • 200 Fail Labels
  • 250 PassWrap Cable Labels
  • Earth Bond Test Lead
  • 230V Extension Lead Adaptor
  • Mains Lead
  • 6 x Rechargeable Batteries
  • HPAT400 Carry Case
  • Portable Appliance Tester Kit Carry Case
  Kit A Kit B Kit C Kit D
Martindale HPAT400 PAC Checker
Microwave Leakage Detector    
50 Microwave Emissions Labels    
PAT Certificate Pad    
PAT Register Book w/ Frequency of Inspection
IEC Clover Leaf Adaptor  
Martindale CP501 Check Plug  
1000 Pass Labels
200 Fail Labels
250 PassWrap Cable Labels
250 Tuff Tag Cable Labels    
Earth Bond Test Lead
Mains Lead
230V Extension Lead Adaptor
110V Appliance Adaptor    
110V Extension Lead Adaptor    
Rechargeable Batteries
HPAT400 Carry Case
Portable Appliance Tester Kit Carry Case  

Specification

EARTH CONTINUITY

  • Test voltage: 4V DC (into open circuit) Test current: 200mA DC (into short circuit)
  • Accuracy: ± 0.03Ω
  • Pass limits: Lead ≤ 0.20 Ω = PASS; Class I ≤ 0.20 Ω = PASS

INSULATION

  • Fixed voltage: >500V DC at 1mA (< 625V DC into open circuit)
  • Test current: 1.5mA (into short circuit)
  • Accuracy: ± 0.1MΩ
  • Pass limits: Lead: ≥ 1.0 MΩ; Class I: ≥ 1.0 MΩ; Class II: ≥ 2.0 MΩ

FUSE CHECK

  • Test voltage: 4V DC (into open circuit)
  • Test current: 200mA DC (into short circuit)
  • Pass level: >2mA

GENERAL

  • Overload protection: 300V AC/DC

Supplied Accessories

  • Martindale HPAT400 PAT Tester (complete with Earth Bond Lead & Crocodile Clip, Mains Lead, 230V Extension Lead Adaptor, HPAT400 Instruction Manual, 6 x Rechargeable Batteries and Carry Case).
  • Microwave Leakage Detector
  • 150 Microwave Emission Labels
  • PAT Certificate Pad
  • PAT Register Book w/ Frequency of Inspection
  • IEC Clover Leaf Adaptor
  • Martindale CP501 Socket Tester
  • 1000 Pass Labels
  • 200 Fail Labels
  • 250 PassWrap Cable Labels

Please note that there may be delays on delivery of this product. For more information please 0113 248 9966.

Martindale HPAT400 PAT Test Kit C allows the user to test appliances and leads in residential and office premises and then carry out reporting and certification with a useful software package.

The Martindale HPAT400 PAC Checker has automatic test sequences for Class I appliances, Class II appliances and power leads. Once the test is correctly connected, all the user needs to do is press the appropriate button to initiate the test. A PASS/FAIL indication is provided for each test in the sequence alongside an overall indication. This means that the HPAT400 is unsuitable for long extension leads. Tests include earth bond, insulation resistance, leakage current and polarity checking.

Martindale HPAT400 Kit C includes SimplyPATs V7 Manual Software. This useful software package allows the user to keep track of data, customer information, and test sites as well as producing invoices and certification as required. Other accessories in Kit C include adaptors, PAT labels and a socket tester.

Martindale HPAT400 Kit C Includes:

  • Martindale HPAT400 PAC Checker
  • SimplyPATs Version 7 Manual PAT Software
  • PAT Register Book w/ Frequency of Inspection
  • IEC Clover Leaf Adaptor
  • Martindale CP501 Socket Tester
  • 1000 Pass Labels
  • 200 Fail Labels
  • 250 PassWrap Cable Labels
  • Earth Bond Test Lead
  • 230V Extension Lead Adaptor
  • Mains Lead
  • 6 x Rechargeable Batteries
  • HPAT400 Carry Case
  • Portable Appliance Tester Kit Carry Case
  Kit A Kit B Kit C Kit D
Martindale HPAT400 PAC Checker
Microwave Leakage Detector    
50 Microwave Emissions Labels    
PAT Certificate Pad    
PAT Register Book w/ Frequency of Inspection
IEC Clover Leaf Adaptor  
Martindale CP501 Check Plug  
1000 Pass Labels
200 Fail Labels
250 PassWrap Cable Labels
250 Tuff Tag Cable Labels    
Earth Bond Test Lead
Mains Lead
230V Extension Lead Adaptor
110V Appliance Adaptor    
110V Extension Lead Adaptor    
Rechargeable Batteries
HPAT400 Carry Case
Portable Appliance Tester Kit Carry Case  

EARTH CONTINUITY

  • Test voltage: 4V DC (into open circuit) Test current: 200mA DC (into short circuit)
  • Accuracy: ± 0.03Ω
  • Pass limits: Lead ≤ 0.20 Ω = PASS; Class I ≤ 0.20 Ω = PASS

INSULATION

  • Fixed voltage: >500V DC at 1mA (< 625V DC into open circuit)
  • Test current: 1.5mA (into short circuit)
  • Accuracy: ± 0.1MΩ
  • Pass limits: Lead: ≥ 1.0 MΩ; Class I: ≥ 1.0 MΩ; Class II: ≥ 2.0 MΩ

FUSE CHECK

  • Test voltage: 4V DC (into open circuit)
  • Test current: 200mA DC (into short circuit)
  • Pass level: >2mA

GENERAL

  • Overload protection: 300V AC/DC
  • Martindale HPAT400 PAT Tester (complete with Earth Bond Lead & Crocodile Clip, Mains Lead, 230V Extension Lead Adaptor, HPAT400 Instruction Manual, 6 x Rechargeable Batteries and Carry Case).
  • Microwave Leakage Detector
  • 150 Microwave Emission Labels
  • PAT Certificate Pad
  • PAT Register Book w/ Frequency of Inspection
  • IEC Clover Leaf Adaptor
  • Martindale CP501 Socket Tester
  • 1000 Pass Labels
  • 200 Fail Labels
  • 250 PassWrap Cable Labels