Seaward Apollo 400+ Elite Printer Kit (380A9906)
- Includes Seaward Elite Test N Tag Printer with labels
- Useful carry case holds tester, printer and all accessories
- 110V adaptor kit and Seaward barcode scanner included
The Seaward Apollo 400+ PAT Tester has had a major revamp. It now has extensively updated firmware which has improved the interface compared to the old Apollo 400 tester as well as introducing a database search function. There is also an external battery pack which allows the rechargeable battery to be changed in the field with minimal disruption so the user can carry on testing when the battery runs out.
The Seaward Apollo 400+ is one of the most straight-forward and efficient PAT instruments on the market, providing inbuilt storage for up to 2000 appliance records and 25 auto sequence tests. A firmware update and an external battery pack have now been added to the tester.
The Elite Printer Kit includes both the Seaward Test n' Tag ELITE Printer and the Seaward Barcode Scanner. Offering custom label printing, the Test 'n' Tag ELITE allows users to include asset number, username, test status, barcode, test date and next date due on their labels, as well as the option to add their name, company or logo for a more professional appearance. The printer is also cheap to run, benefiting from a low running cost of less than 10p per label.
The Seaward Barcode Scanner is another very useful time-saving tool, allowing the user to scan printed PAT label barcodes to retrieve previous information, eliminating the need for repeat data logging.
Seaward part number: 380A9906
Seaward Apollo 400+ PAT Tester Main Features:
- Downloadable PAT tester with built-in QWERTY keyboard
- Battery-powered, portable tester (weighing just 1.5kg)
- Store and download up to 2000 apppliance records
- Features 25 pre-defined auto sequence tests
- Connects via Bluetooth to Seaward PAT printers and scanners
- Carry out tests to ensure full compliance with the 4th Edition IET Code of Practice
- Suitable for point to point testing for fixed appliances
- Compatible with Seaward PATGuard 3 software
- The basic model within Seaward's Apollo range (includes Apollo 400+/500+/600+)
- Supplied with UKAS calibration certificate and a 2 year warranty
Seaward Apollo 400 Elite Printer Kit Includes:
- Seaward Apollo 400+ PAT Tester & included accessories
- Seaward Test n’ Tag ELITE 2 Printer
- Bluetooth Barcode Scanner
- Seaward Apollo Carry Case 71G109
- 110V Appliance Adaptor
- 110V Extension Lead Adaptor
For more information on the Seaward Apollo 400+ PAT Tester, please click here.
We Have A Choice Of Five Seaward Apollo 400+ Kits
PATGuard Elite Kit | Pro Printer Kit | Pro Printer + PATGuard Elite Kit | Elite Printer Kit | Elite Printer + PATGuard Elite Kit | |
---|---|---|---|---|---|
Seaward Apollo 400+ Included Accessories | ✔ | ✔ | ✔ | ✔ | ✔ |
Seaward PATGuard Elite 3 | 1-Year (Upgradable) | 1-Year (Upgradable) | 1-Year (Upgradable) | ||
Online Training Voucher | ✔ | ||||
Seaward Test n' Tag PRO Printer | ✔ | ✔ | |||
Seaward Test n Tag ELITE 2 Printer | ✔ | ✔ | |||
Bluetooth Barcode Scanner | ✔ | ✔ | ✔ | ✔ | |
Seaward Apollo Carry Case 71G109 | ✔ | ✔ | ✔ | ✔ | |
110V Appliance Adaptor | ✔ | ✔ | ✔ | ✔ | ✔ |
110V Extension Lead Adaptor | ✔ | ✔ | ✔ | ✔ | ✔ |
IEC Adaptor Kit | ✔ | ||||
1000 Pass Labels, 200 Fail Labels & 250 Pass Wrap Labels |
✔ |
Earth Continuity
- Test Current: +/- 200mA DC
- Display Range: 0.01 – 19.99Ω
- Pass Value: User Defined
Insulation Resistance
- Test Voltage: 500V / 250VDC @ 1mA nominal
- Display Range: 0.01MΩ - 19.99MΩ
- Pass Value: User Defined
IEC Lead Test
- Test voltage: 5VAC nominal
- Test: Live / Neutral Checks for o/c, s/c and crossed
Protective Conductor Current/Load
- Test Voltage: Supply voltage, maximum load current 16A
- Display Ranges: 0.01mA to 19.99mA
- Pass Value: User Defined
Touch Current
- Test Voltage: Supply Voltage, maximum load current 16A
- Display Range: 0.00 – 3.50mA
- Pass Value: User defined
Load Power/Current
- Test Voltage: Supply Voltage, maximum load current 16A
- Test Duration: Programmable up to a maximum of 255s depending on load. i.e. max duration is reduced for high loads.
- Display Range: 0.00kVA – 4.00kVA, 0.00A – 16.00A
Alternative Leakage Current
- Test Voltages: >25VAC <50VAC
- Display Range: 0.00mA to 19.99mA
- Pass Value: User Defined
RCD Test
- Test Voltage: 230V +10%, -15%
- Test Current: 30mA / 150mA rms sinusoidal
- Display Range: 0ms - 2000ms (30mA), 0-40ms (150mA)
- Test method: Internal isolation to avoid tripping distribution board RCD
Power Socket Test
- Voltage Range: 207V – 253VAC
- Indicates configuration of voltage potential:- Line potential phase to earth, Line potential phase to neutral, Line potential neutral to earth
General
- Memory size: 2000 records
- Weight: 1.5kg
- Dimensions: 230mm x 150mm x 100mm
- Power Source: Mains or rechargeable battery pack
The Seaward Apollo 400+ Elite Printer Kit comes with:
- Seaward Apollo 400+ PAT Tester & included accessories
- Seaward Test n’ Tag ELITE 2 Printer
- Bluetooth Barcode Scanner
- Seaward Apollo Carry Case 71G109
- 110V Appliance Adaptor
- 110V Extension Lead Adaptor