COVID-19: Open for business - Click for more info.

FREE DELIVERY ON ORDERS OVER £150,
WITH NEXT-DAY OPTIONS ALSO AVAILABLE

Kewtech EZYPAT Kit C

  • Ideal for routine in-house PAT testing of power tools and office equipment
  • Adaptors included for 110V appliances and power tools and IEC leads
  • Microwave leakage detector and socket tester provide additional capabilities

£459.00 EXC. VAT

IN STOCK

Description

Kewtech EZYPAT Kit C is a comprehensive solution to low-volume PAT testing on construction sites and in offices. The main instrument in the kit is the Kewtech EZYPAT PAT Tester. This tester can perform earth bond, insulation, substitute leakage and polarity checks in automatic test sequences for Class I appliances, Class II appliances and IEC/extension leads. Clearly-labelled push buttons make the tester very easy to use and results are clearly shown on the bright digital screen.

There is a full range of adaptors in Kewtech EZYPAT Kit C for 110V appliances and extension leads as well as IEC leads and power cords often used in IT and audiovisual equipment. Additionally, there is a socket tester and a microwave leakage detector whilst a PAT certificate pad and register book make it easy to record test results. There are PAT labels for both indoor and outdoor use and there is a Kewtech carry case for all the components.

For more information on the Kewtech EZYPAT PAT Tester, please click here.

Kit Contents

  • Kewtech EZYPAT PAT Tester
  • Two rolls of PASS label rolls (x500)
  • FAIL label roll (x200)
  • PassWrap labels (x250)
  • Tuff Tag labels (x250)
  • Microwave labels (x50)
  • 2 x PAT register books
  • IEC adaptor kit
  • Kewtech KT103 socket tester
  • 110V appliance adaptor
  • 110V extension lead adaptor
  • IEC adaptor kit
  • Microwave leakage detector
  • PAT certificate pad
  • PAT register book

  Kit A Kit B Kit C
Kewtech EZYPAT PAT Tester
PASS labels x2 x2 x2
FAIL labels
PassWrap labels
Tuff Tag Pass Labels  
PAT certificate pad
PAT registerbook x1 x1 x2
IEC clover leaf adaptor    
IEC adaptor kit  
110V appliance adaptor  
110V extension lead adaptor  
Kewtech KT103 Socket Tester
Microwave leakage detector
Microwave emission labels
Kewtech KITBAG2 carry case

Specification

Protective Conductor Resistance

  • Measuring range: 0.00 - 20.00 Ω (NULL value inc)*
  • Over-range indication: > 20.00 Ω
  • Resolution: 0.01Ω
  • Open-circuit voltage: 5 V ±0.4 V DC
  • Measuring current: 200 mA DC (nominal value)
  • Accuracy: ±3%rdg ±5dgt

Insulation

  • Rated voltage: 250V / 500V
  • Measuring range: 0.00 - 20.00 MΩ
  • Over-range indication: > 20.00 MΩ
  • Resolution: 0.01 MΩ
  • No-load voltage: 250 V DC +20%, -0% / 500 V DC +20%, -0%
  • Short-circuit current: 1.5 mA DC or less
  • Rated current: 1 -1.2 mA with a load of 0.25 MΩ / 1 to 1.2 mA with a load of 0.5 MΩ
  • Accuracy: ±2%rdg±3dgt

Substitute Leakage

  • Measuring range: 0.10 - 12.00 mA rms
  • Over-range indication: > 12.00 mA
  • Resolution: 0.01mA
  • Open-circuit voltage/ Freq.: 30 V ±5 V rms / 50 Hz ±5%
  • Measuring current: 1.2 mA AC ±0.5 mA (when measuring 12.00 mA)
  • Accuracy: ±3%rdg±5dgt

Applicable Standards

  • Safety: IEC/EN61010-1 CAT II 300V-instrument; IEC/EN61010-2-030; IEC/EN61010-031 CAT III 600V
  • EMC: EN61326-1, 2-2
  • Possible number of measurements where battery voltage is within the effective range (measuring every 30 sec): Approx. 1400 times (CLI Rpe: 0 Ω, Rins: 1.1 MΩ)

Supplied Accessories

  • Kewtech EZYPAT PAT Tester
  • Two rolls of PASS label rolls (x500)
  • FAIL label roll (x200)
  • PassWrap labels (x250)
  • Tuff Tag labels (x250)
  • Microwave labels (x50)
  • 2 x PAT register books
  • IEC adaptor kit
  • Kewtech KT103 socket tester
  • 110V appliance adaptor
  • 110V extension lead adaptor
  • IEC adaptor kit
  • Microwave leakage detector
  • PAT certificate pad
  • PAT register book

Kewtech EZYPAT Kit C is a comprehensive solution to low-volume PAT testing on construction sites and in offices. The main instrument in the kit is the Kewtech EZYPAT PAT Tester. This tester can perform earth bond, insulation, substitute leakage and polarity checks in automatic test sequences for Class I appliances, Class II appliances and IEC/extension leads. Clearly-labelled push buttons make the tester very easy to use and results are clearly shown on the bright digital screen.

There is a full range of adaptors in Kewtech EZYPAT Kit C for 110V appliances and extension leads as well as IEC leads and power cords often used in IT and audiovisual equipment. Additionally, there is a socket tester and a microwave leakage detector whilst a PAT certificate pad and register book make it easy to record test results. There are PAT labels for both indoor and outdoor use and there is a Kewtech carry case for all the components.

For more information on the Kewtech EZYPAT PAT Tester, please click here.

Kit Contents

  • Kewtech EZYPAT PAT Tester
  • Two rolls of PASS label rolls (x500)
  • FAIL label roll (x200)
  • PassWrap labels (x250)
  • Tuff Tag labels (x250)
  • Microwave labels (x50)
  • 2 x PAT register books
  • IEC adaptor kit
  • Kewtech KT103 socket tester
  • 110V appliance adaptor
  • 110V extension lead adaptor
  • IEC adaptor kit
  • Microwave leakage detector
  • PAT certificate pad
  • PAT register book

  Kit A Kit B Kit C
Kewtech EZYPAT PAT Tester
PASS labels x2 x2 x2
FAIL labels
PassWrap labels
Tuff Tag Pass Labels  
PAT certificate pad
PAT registerbook x1 x1 x2
IEC clover leaf adaptor    
IEC adaptor kit  
110V appliance adaptor  
110V extension lead adaptor  
Kewtech KT103 Socket Tester
Microwave leakage detector
Microwave emission labels
Kewtech KITBAG2 carry case

Protective Conductor Resistance

  • Measuring range: 0.00 - 20.00 Ω (NULL value inc)*
  • Over-range indication: > 20.00 Ω
  • Resolution: 0.01Ω
  • Open-circuit voltage: 5 V ±0.4 V DC
  • Measuring current: 200 mA DC (nominal value)
  • Accuracy: ±3%rdg ±5dgt

Insulation

  • Rated voltage: 250V / 500V
  • Measuring range: 0.00 - 20.00 MΩ
  • Over-range indication: > 20.00 MΩ
  • Resolution: 0.01 MΩ
  • No-load voltage: 250 V DC +20%, -0% / 500 V DC +20%, -0%
  • Short-circuit current: 1.5 mA DC or less
  • Rated current: 1 -1.2 mA with a load of 0.25 MΩ / 1 to 1.2 mA with a load of 0.5 MΩ
  • Accuracy: ±2%rdg±3dgt

Substitute Leakage

  • Measuring range: 0.10 - 12.00 mA rms
  • Over-range indication: > 12.00 mA
  • Resolution: 0.01mA
  • Open-circuit voltage/ Freq.: 30 V ±5 V rms / 50 Hz ±5%
  • Measuring current: 1.2 mA AC ±0.5 mA (when measuring 12.00 mA)
  • Accuracy: ±3%rdg±5dgt

Applicable Standards

  • Safety: IEC/EN61010-1 CAT II 300V-instrument; IEC/EN61010-2-030; IEC/EN61010-031 CAT III 600V
  • EMC: EN61326-1, 2-2
  • Possible number of measurements where battery voltage is within the effective range (measuring every 30 sec): Approx. 1400 times (CLI Rpe: 0 Ω, Rins: 1.1 MΩ)
  • Kewtech EZYPAT PAT Tester
  • Two rolls of PASS label rolls (x500)
  • FAIL label roll (x200)
  • PassWrap labels (x250)
  • Tuff Tag labels (x250)
  • Microwave labels (x50)
  • 2 x PAT register books
  • IEC adaptor kit
  • Kewtech KT103 socket tester
  • 110V appliance adaptor
  • 110V extension lead adaptor
  • IEC adaptor kit
  • Microwave leakage detector
  • PAT certificate pad
  • PAT register book