Fluke 6500-2 PAT Testing Kit A
- A complete set of PAT testing functions
- Includes 110V adaptor kit, thus enabling PAT testing on construction equipment
- Microwave leakage detector included alongside PASS, FAIL and microwave leakage labels
The Fluke 6500-2 Portable Appliance Tester is a professional instrument designed to meet the needs of high volume PAT testers and electrical contractors.
Now featuring a full colour display, the Fluke 6500-2 takes over from the popular 6500 model, offering all the functionality of its popular predecessor with a range of additional benefits such as 250V insulation resistance testing, portable RCD testing and active 110V appliance testing (using Fluke adaptors).
The Fluke 6500-2 PAT Tester stores up to 1000 test results with simple data transfer to a PC and an additional USB port for connecting to an optional printer.
Weighing around 3kg, the Fluke 6500-2 is one of the lightest professional PAT testers on the market, ideal for extended safety testing of electrical equipment in a range of locations.
Fluke 6500-2 PAT Testing Kit A Includes:
- Fluke 6500-2 PAT Tester (complete with test lead with detachable clip and probe, mains lead, USB stick, USB cable, instruction manual, calibration certificate and Fluke carry case)
- 1000 Pass Labels
- 200 Fail Labels
- 250 PassWrap Labels
- Fluke 110V Adaptor Kit
- 110V Extension Lead Adaptor
- 230V Extension Lead Adaptor
- Microwave Leakage Detector
- Microwave Emission Labels
- IEC Adaptor Kit
- TEK989 Socket Tester
For more information on the Fluke 6500-2 Portable Appliance Tester please click here.
Kit A | Kit B | Kit C | Kit D | Starter Kit | |
---|---|---|---|---|---|
Fluke 6500-2 PAT Tester | ✔ | ✔ | ✔ | ✔ | ✔ |
SimplyPATs Version 7 Software | ✔ | ✔ | ✔ | ||
Fluke 0702/PAT Software | ✔ | ||||
Barcode Scanner | ✔ | ✔ | |||
Fluke SP6000 Mini Printer | ✔ | ||||
Barcode ID Labels | ✔ | ||||
Fluke 110V Adaptor Kit | ✔ | ✔ | ✔ | ✔ | |
IEC Adaptor Kit, 110V & 230V Extension Lead Adapter | ✔ | ✔ | ✔ | ✔ | |
EXTL100 Extension Lead Adaptor | ✔ | ||||
1000 Pass Labels, 200 Fail Labels & 250 PassWrap Labels | ✔ | ✔ | ✔ | ✔ | |
Pass 560R Labels | ✔ | ||||
Microwave Leakage Detector & Microwave Emission Labels | ✔ | ✔ | ✔ | ✔ | |
TEK989 Socket Tester | ✔ | ✔ | ✔ | ✔ |
Power-on Test
- The test indicates reversed L-N, missing PE, and measures the mains voltage and frequency.
- Display Range : 90 V to 264 V
- Accuracy at 50 Hz: ± (2% + 3 counts)
- Resolution: 0.1 V
- Input Impedance: > 1 MΩ // 2.2 nF
- Maximum Input Mains Voltage: 264 V
Earth Bond Test (Rpe)
- Display Range: 0 to 19.99 Ω
- Accuracy (After Bond Test Zeroing): ± (5% + 4 counts)
- Resolution: 0.01 Ω
- Test Current: 200 mA AC -0% +40% into 1.99 Ω; 25 A AC ± 20% into 25 mΩ at 230 V
- Open Circuit Voltage: > 4 V AC, < 24 V AC
- Bond Test Zeroing: Can subtract up to 1.99 Ω
Insulation Test (Riso)
- Display Range: 0 to 299 MΩ
- Accuracy: ± (5% + 2 counts) from 0.1 to 300 MΩ
- Resolution: 0.01 MΩ (0 to 19.99 MΩ) / 0.1 MΩ (20 to 199.9 MΩ) / 1 MΩ (200 to 299 MΩ)
- Test Voltage: 500 V DC -0% + 25% at 500 kΩ load or 250 V dc -0 % +25 % at 250 kΩ load
- Test Current: > 1 mA at 500 kΩ load, < 15 mA at 0 Ω
- Auto Discharge Time: < 0.5 s for 1 μF
- Max. Capacitive Load: Operational up to 1 μF
Touch Current Test
- Display Range: 0 to 1.99 mA AC
- Accuracy: ± (4% + 2 counts)
- Resolution: 0.01 mA
- Internal Resistance (via Probe): 2 kΩ
- Measuring Method: Probe*
Substitute Leakage Current Test
- Display Range: 0 to 19.99 mA AC
- Accuracy: ± (2.5% + 3 counts)
- Resolution: 0.01 mA
- Test Voltage: 100 V AC ± 20%
Load/Leakage Test: Load Current
- Display Range: 0 A to 13 A
- Accuracy: ± (4% + 2 counts)
- Resolution: 0.1 A*
Load/Leakage Test: Load Power
- Display Range 230 V Mains: 0.0 VA to 3.2 kVA
- Accuracy: ± (5 % + 3 counts)
- Resolution: 1 VA (0 to 999 VA), 0.1 kVA (>1.0 kVA)*
Load/Leakage Test: Leakage Current
- Display Range: 0 to 19.99 mA
- Accuracy: ± (4% + 4 counts)
- Resolution: 0.01 mA*
PELV Test
- Accuracy at 50 Hz: ± (2% + 3 counts)
- Overload Protection: 300 V rms
- Warning Threshold: 25 V rms
RCD Test: Trip Current
- Operational Error: ±10 %
- Nominal: 30 mA
- Accuracy: ±5 %
RCD Test: Trip Time
- Standard Requirement: 61557 Part 6; tolerance of rated test current 0 % to +10 %
- Operational Error: ±10 %
- RCD Type: AC general-purpose 30 mA
- Display Range: 310 ms
- Resolution: 0.1 ms
- Accuracy: 3 ms
- Trip Time Limit at 100 % (30 mA): 300 ms
- Trip Time Limit at 500 % (150 mA): 40 ms
*The appliance under test is energised at mains voltage.
Environmental
- Operating Temperature: 0 to 40 °C
- Relative Humidity: Non condensing < 10 °C / 95% from 10 to 30 °C / 75% from 30 to 40 °C
Safety
- Safety Rating: Complies with EN61010-1 3rd edition / CAT II, 300 V, pol 2
General
- Size: 200 mm (L) x 275 mm (W) x 114 mm (H)
- Weight: 3.13 kg
- Power Supply: 230 V +10 % -15 %, 50 Hz ±2 Hz or (6500-2 only: 110V +10 % -15 %,50 Hz ±2 Hz)
- Power Consumption (Tester): 13 W typical (idle) / 60 W max. during 25A Bond test
- Storage Temperature: -10 to 60 °C
- Corrosion: 70 °C @ 95 % RH for 5 days max.
- Operating Altitude: 0 up to 2000 m
- Sealing: IP-40 (enclosure), IP-20 (connectors)
- EMC: Complies with EN61326-1, portable
- EMI Immunity: 3 V/m
- Fluke 6500-2 PAT Tester (complete with test lead with detachable clip and probe, mains lead, USB stick, USB cable, instruction manual, calibration certificate and Fluke carry case)
- 1000 Pass Labels
- 200 Fail Labels
- 250 PassWrap Labels
- Fluke 110V Adaptor Kit
- 110V Extension Lead Adaptor
- 230V Extension Lead Adaptor
- Microwave Leakage Detector
- Microwave Emission Labels
- IEC Adaptor Kit
- TEK989 Socket Tester