BATTPAT Kit A
- Quickly test multiple appliances with one-button testing
- Suitable for 230V appliances and extension leads with adaptor
- Record results using PAT certificate pad, PAT register book and multiple labels
The First Stop Safety BattPAT is a battery powered portable appliance checker offering extremely quick and simple operation. Earth bond, insulation and IEC lead testing can all be performed at the press of a button with LED indication of whether the appliance has passed or failed.
Ideal for beginners, the entry level BattPAT is a lightweight PAC checker perfectly suited to low volume portable appliance testing in homes, shops and offices
Complete with a rugged design and rechargeable battery pack, the Batt PAT is capable of performing up to 500 PAT tests per charge.
First Stop Safety BattPAT Kit A Includes:
- First Stop Safety BattPAT PAC Checker (supplied with Earth Bond Lead & Crocodile Clip, 230V Extension Lead Adaptor and BattPAT Instruction Manual).
- Microwave Leakage Detector
- 50 Microwave Emission Labels
- PAT Certificate Pad
- PAT Register Book w/ Frequency of Inspection
- IEC Clover Leaf Adaptor
- TEK989 Socket Checker
- 1000 Pass Labels
- 200 Fail Labels
- 250 PassWrap Cable Labels
For more information on the BattPAT Portable Appliance Tester please click here.
Kit A | Kit B | Kit C | Kit D | |
---|---|---|---|---|
BATTPAT | ✔ | ✔ | ✔ | ✔ |
First Stop Safety PAT Testing DVD | ✔ | ✔ | ||
First Stop Safety PAT Testing Guide Book | ✔ | |||
Microwave Leakage Detector | ✔ | ✔ | ✔ | ✔ |
Microwave Emission Labels x 50 | ✔ | ✔ | ✔ | ✔ |
PAT Certificate Pad | 1 | 1 | 2 | |
PAT Register Book | ✔ | ✔ | ✔ | |
SimplyPATs Version 7 Software | ✔ | |||
IEC Clover Leaf Adaptor | ✔ | ✔ | ||
IEC Adaptor Kit | ✔ | ✔ | ||
110V Appliance Adaptor | ✔ | ✔ | ||
110V Extension Lead Adaptor | ✔ | ✔ | ||
TEK989 Socket Checker | ✔ | ✔ | ✔ | ✔ |
Pass Labels x 1000 | ✔ | ✔ | ✔ | ✔ |
Fail Labels x 200 | ✔ | ✔ | ✔ | ✔ |
PassWrap Labels x 250 | ✔ | ✔ | ✔ | ✔ |
Tuff Tag Pass Labels x 250 | ✔ | ✔ | ||
Carry Case | ✔ | ✔ | ✔ |
- Earth Continuity Test: Test current 150mA
- Pass Levels: < 0.25 ohms for leads up to 10m; <0.5 ohms - leads up to 25m
- Insulation Test: 350 Volts DC
- Dimensions: 45cm x 28.5 cm x 13 cm
- Weight: 1.1 kg
BATTPAT Kit A comes with:
- First Stop Safety BattPAT PAC Checker (supplied with Earth Bond Lead & Crocodile Clip, 230V Extension Lead Adaptor and BattPAT Instruction Manual).
- Microwave Leakage Detector
- 50 Microwave Emission Labels
- PAT Certificate Pad
- PAT Register Book w/ Frequency of Inspection
- IEC Clover Leaf Adaptor
- TEK989 Socket Checker
- 1000 Pass Labels
- 200 Fail Labels
- 250 PassWrap Cable Labels