Metrel GammaPAT Lite Kit B
- PAT certificate pad, register book and labels for recording results
- Microwave leakage detector, socket tester and adaptors
- Metrel PAT testing guidance DVD with hints and tips
PAT testing can be performed in either simple or auto mode with test values and Pass/Fail indication clearly displayed upon completion of each test. In addition the Metrel GammaPAT tester has a built in charger ensuring that a full day of PAT testing can be performed.
The MI3311 GammaPAT Lite also has an onboard memory capable of storing up to 1700 test results complete with appliance ID/description. These can then be downloaded using additional PAT software found with the Metrel GammaPAT Pro Kits.
The Metrel GammaPAT Lite is the ideal choice for both novice and more advanced users with a moderate number of appliances to test.
Metrel GammaPAT Lite Test Kit B Includes:
- Metrel MI3311 GammaPAT Lite PAT Tester (complete with Earth Test Lead, 230V Extension Lead Adaptor, GammaPAT Instruction Manual, 6 x Rechargeable Batteries, Calibration Certificate and Carry Case).
- Microwave Leakage Detector
- 50 Microwave Emission Labels
- 2 x PAT Certificate Pad
- PAT Register Book w/ Frequency of Inspection
- 110V Appliance Adaptor
- 110V Extension Lead Adaptor
- IEC Adaptor Kit
- Metrel TEK989 Socket Tester
- 1000 Pass Labels
- 200 Fail Labels
- 250 PassWrap Cable Labels
- 250 Tuff Tag Pass Cable Labels
For more detailed information on the Metrel GammaPAT Lite Portable Appliance Tester please click here.
Kit A | Kit B | |
---|---|---|
Metrel MI3311 GammaPAT Tester | ✔ | ✔ |
Metrel TEK 989 Socket Tester | ✔ | |
Microwave Leakage Detector | ✔ | ✔ |
50 Microwave Emmisions Labels | ✔ | ✔ |
PAT Register Book w/ Frequency of Inspection | ✔ | ✔ |
PAT Certificate Pad | ✔ | ✔ |
IEC Clover Leaf Adaptor | ✔ | |
IEC PAT Adaptor Kit | ✔ | |
110V Appliance Adaptor | ✔ | |
110V Extension Lead Adaptor | ✔ | |
1000 Pass Labels | ✔ | ✔ |
200 Fail Labels | ✔ | ✔ |
250 PassWrap Cable Labels | ✔ | ✔ |
Earth Test Lead | ✔ | ✔ |
230V Extension Lead Adaptor | ✔ | ✔ |
Calibration Certificate | ✔ | ✔ |
GammaPAT Carry Case | ✔ | ✔ |
6 x Rechargeable Batteries | ✔ | ✔ |
- Earth Bond Continuity: Test current of 200mA
- Insulation Test: 50V or 500V DC Measuring range: 0.1 - 19.99 Mohms
- Substitute Leakage Test: Carried out at 40V DC
- Insulation-S Test: Insulation resistance of isolated accessible conductive parts.
- Substitute Leakage-S: Substitute leakage current of isolated accessible conductive parts
- Polarity Test: IEC and Extension Lead internal wiring check.
- Weight & Dimensions: 1kg - 230x140x80
- Metrel MI3311 GammaPAT Lite PAT Tester (complete with Earth Test Lead, 230V Extension Lead Adaptor, GammaPAT Instruction Manual, 6 x Rechargeable Batteries, Calibration Certificate and Carry Case).
- Microwave Leakage Detector
- 50 Microwave Emission Labels
- 2 x PAT Certificate Pad
- PAT Register Book w/ Frequency of Inspection
- 110V Appliance Adaptor
- 110V Extension Lead Adaptor
- IEC Adaptor Kit
- Metrel TEK989 Socket Tester
- 1000 Pass Labels
- 200 Fail Labels
- 250 PassWrap Cable Labels
- 250 Tuff Tag Pass Cable Labels