Kewtech SMARTPAT Pro Kit
- Perform load & run and PRCD testing using Kewtech SMARTPAT PAT tester
- Print customised PAT labels with the KEW-80L printer and KEWPAT App
- Includes 110V adaptors for appliances and extension leads plus IEC adaptor set
***SPECIAL OFFER: This product is currently available with 5 FREE KEW-80L Printer Label Rolls!***
The Kewtech SMARTPAT Pro Kit includes the Kewtech SMARTPAT PAT Tester which is the most sophisticated tester within the Kewtech range. The tester is capable of performing tests including earth bond/continuity testing, insulation resistance tests, polarity checking and substitute leakage testing as well as mains operated tests including 230V load/leakage tests, extended-duration earth bond tests, and portable RCD testing. Uniquely, the Kewtech SMARTPAT even performs mains powered testing on 110V appliances as well as 230V (access to applicable voltage supply required).
KEWPAT App
The full capabilities of the Kewtech SMARTPAT Tester are best utilised when operated through the KEWPAT App which is available to download free of charge on Apple IOS and Android devices. Using this app the operator can use the QWERTY keyboard within their device to input appliance/test information. All results and data are stored on the device and you are able to use the camera to tag appliance images against the results, create and share professional reports in PDF, access the inbuilt risk assessment calculator, create preferred auto test sequences as well as printing/scanning QR Codes/Barcodes. To communicate with the KEW-80L Bluetooth label printer the user would also need to install and use the KEWPAT App.
Kewtech KEW-80L PAT Label Printer
The SmartPAT Pro kit also includes the KEW-80L printer which is a small and portable Bluetooth thermal printer that prints barcode or QR code labels as well as standard Pass/Fail PAT labels (use of the KEWPAT App required). Printing and affixing the QR code labels will significantly speed up re-testing appliances by scanning the labels using the scanner within the App to speed up any subsequent re-tests. Your company logo can also be added to the printed label.
In addition to the PAT tester, printer and standard accessories, the SmartPAT Pro Kit is supplied with 3 x 110V 16A adaptors for appliance, extension leads and powered tests, an IEC adaptor set allows testing on leads used for IT and audiovisual equipment, 2 rolls of labels for the printer and a Kewtech carry bag.
Key Features
- Tester operated via Bluetooth by KEWPAT Android/Apple app
- Performs Load/Leakage tests on 230V and 110V appliances
- Kit is supplied with KEW-80L label printer
- Scan QR codes or barcodes to speed up re-testing
- Use your smartphone camera to tag images to test records.
- Create professional PDF reports within the KewPAT app.
- Get signature from customer in the PATApp to confirm job completion
- Dropdown menus for customer, site, location and description
- Add and amend your own customised Auto Sequence tests
- Company logo can be added to reports and printed labels
- Use the inbuilt risk assessment calculator to determine the recommended re-test frequency
Kit Contents
- Kewtech SMARTPAT PAT Tester + standard accessories
- Kewtech KEW-80L PAT label printer
- 5 x Kewtech KEW80 PAT label rolls
- 110V 16A appliance adaptor
- 110V 16A extension lead adaptor
- 110V 16A power adaptor
- Kewtech KITBAG2 carry case
- IEC clover leaf adaptor
Protective Conductor Resistance Test
- Measuring range: 0.00 - 20.00 Ω (NULL value inc)*
- Over-range indication: > 20.00 Ω
- Resolution: 0.01Ω
- Open-circuit voltage: 5 V ±0.4 V DC
- Measuring current: 200 mA DC (nominal value)
- Accuracy: ±3%rdg ±5dgt
Mains Voltage
- Display range: 30 - 270 V
- Hi/ Lo indication: < 30 V: No voltage indication; > 270 V: 270 V
- Resolution & Accuracy: 1 V & ±3%rdg ±5dgt
Insulation
- Rated voltage: 250V / 500V
- Measuring range: 0.00 - 20.00 MΩ
- Over-range indication: > 20.00 MΩ
- Resolution: 0.01 MΩ
- No-load voltage: 250 V DC +20%, -0% / 500 V DC +20%, -0%
- Short-circuit current: 1.5 mA DC or less
- Rated current :1 -1.2 mA with a load of 0.25 MΩ 1 to 1.2 mA with a load of 0.5 MΩ
- Accuracy: ±2%rdg±3dgt
Substitute Leakage
- Measuring range 0.10 - 12.00 mA rms
- Over-range indication > 12.00 mA
- Resolution 0.01mA
- Open-circuit voltage/ Freq. 30 V ±5 V rms / 50 Hz ±5%
- Measuring current 1.2 mA AC ±0.5 mA (when measuring 12.00 mA)
- Accuracy ±3%rdg±5dgt
Insulation Test Between L-N
- Open-circuit voltage: 4.5 V ±0.5 V DC
- Criteria of judgement: 100 kΩ ±20 kΩ or less: LCD shows “<0.10 MΩ” and the measurement is halted.
Run Leakage (Item: Load current / Leakage current)
- Mains voltage range: 100 - 253 V / 50 Hz
- Measuring range: 0.10 - 13.00 A rms 0.10 - 20.00 mA rms
- Display range: 0.00 - 13.00 A 0.00 - 20.00 mA
- Over-range indication: > 13.00 A > 20.00 mA
- Resolution: 0.01A / 0.01mA
- Accuracy: ±10%rdg ±5dgt / ±3%rdg ±5dvgt
- Max. rating: 3 kVA max., 15 sec. cont. / -
RCD Test
- Rated voltage 230 V - 15% to +10% / 50Hz
- Rated current 10 mA / 30 mA
- Test duration ×1: 0.0 ms - 500.0 ms / ×5: 0.0 ms - 40.0 ms
- Test current accuracy: 2% - 8%
- Operating time accuracy: ±2 ms ( 40 ms) ±8 ms (>40 ms)
The Kewtech SMARTPAT Pro Kit comes with:
- Kewtech SMARTPAT PAT Tester
- Kewtech KEW-80L PAT label printer
- 5 x Kewtech KEW80 PAT label rolls
- 110V appliance adaptor
- 110V extension lead adaptor
- 110V power adaptor
- Kewtech KITBAG2 carry case
- IEC clover leaf adaptor