COVID-19: Open for business - Click for more info.

FREE DELIVERY ON ORDERS OVER £150,
WITH NEXT-DAY OPTIONS ALSO AVAILABLE

Kewtech EZYPAT Plus Kit C

  • A Kewtech EZYPAT Plus which can perform 230V load & run testing and standard PAT tests
  • 110V power, 110V appliance, 110V extension lead adaptor and IEC adaptor set
  • Microwave leakage detector and socket tester enable additional safety testing

£509.00 EXC. VAT

IN STOCK

Description

Kewtech EZYPAT Plus Kit C includes the Kewtech EZYPAT Plus PAT Tester in addition to a range of useful PAT accessories. The tester itself is one of the few battery-powered testers to perform 230V load & run testing and can also carry out regular PAT tests such as earth bond, insulation resistance, polarity and substitute leakage. It has pre-programmed automatic test sequences for Class I and Class II appliances and IEC/extension leads. Operation is carried out using simple push buttons and results are shown on screen alongside PASS/FAIL indications.

PAT testing accessories in Kewtech EZYPAT Plus Kit C allow the user to carry out more tests on a wide range of appliances. A full set of 110V adaptors is included for testing construction appliances and leads and there is power adaptor for performing powered tests. There is also an IEC adaptor set for leads used for IT and AV equipment. There are also a PAT certificate pad, PAT register books, indoor and outdoor PAT labels, a microwave leakage detector, a socket tester and a carry case.

For more information on the Kewtech EZYPAT Plus PAT Tester, please click here.

Kit Contents

  • Kewtech EZYPAT Plus PAT Tester
  • Two rolls of Pass labels (x500)
  • Fail labels (x200)
  • PassWrap labels (x250)
  • PAT certificate pad
  • PAT register book
  • IEC adaptor kit
  • 110V appliance adaptor
  • 110V extension lead adaptor
  • 110V power adaptor
  • Microwave leakage detector
  • Microwave labels (x50)
  • Tuff Tag Pass labels (x250)
  • Kewtech KT103 socket tester
  • Kewtech KITBAG2 carry case

  Kit A Kit B Kit C
Kewtech EZYPAT Plus PAT Tester
PASS labels x2 x2 x2
FAIL labels
PassWrap labels
Tuff Tag Pass Labels  
PAT certificate pad
PAT registerbook x1 x1 x2
IEC clover leaf adaptor    
IEC adaptor kit  
110V appliance adaptor  
110V extension lead adaptor  
110V power adaptor  
Kewtech KT103 Socket Tester
Microwave leakage detector
Microwave emission labels
Kewtech KITBAG2 carry case

Specification

Protective Conductor Resistance

  • Measuring range: 0.00 - 20.00 Ω (NULL value inc)*
  • Over-range indication: > 20.00 Ω
  • Resolution: 0.01Ω
  • Open-circuit voltage: 5 V ±0.4 V DC
  • Measuring current: 200 mA DC (nominal value)
  • Accuracy: ±3%rdg ±5dgt

Mains Voltage

  • Display range: 30 - 270 V
  • Hi/ Lo indication: < 30 V: No voltage indication; > 270 V: 270 V 
  • Resolution & Accuracy: 1 V & ±3%rdg ±5dgt

Insulation

  • Rated voltage: 250V; 500V
  • Measuring range: 0.00 - 20.00 MΩ
  • Over-range indication: > 20.00 MΩ
  • Resolution: 0.01 MΩ
  • No-load voltage: 250 V DC +20%, -0% 500 V DC +20%, -0%
  • Short-circuit current: 1.5 mA DC or less
  • Rated current: 1 -1.2 mA with a load of 0.25 MΩ 1 to 1.2 mA with a load of 0.5 MΩ
  • Accuracy: ±2%rdg±3dgt

Substitute Leakage

  • Measuring range: 0.10 - 12.00 mA rms
  • Over-range indication: > 12.00 mA
  • Resolution: 0.01mA
  • Open-circuit voltage/ Freq.: 30 V ±5 V rms / 50 Hz ±5%
  • Measuring current: 1.2 mA AC ±0.5 mA (when measuring 12.00 mA)
  • Accuracy: ±3%rdg±5dgt

Insulation Test between L and N

  • Open-circuit voltage: 4.5 V ±0.5 V DC
  • Criteria of judgement: 100 kΩ ±20 kΩ or less: LCD shows “<0.10 MΩ” and the measurement is halted.

Run Leakage (Item: Load current / Leakage current)

  • Mains voltage range: 100 - 253 V / 50 Hz
  • Measuring range: 0.10 - 13.00 A rms / 0.10 - 20.00 mA rms
  • Display range: 0.00 - 13.00 A / 0.00 - 20.00 mA
  • Over-range indication: > 13.00 A / > 20.00 mA
  • Resolution: 0.01A / 0.01mA
  • Accuracy: ±10%rdg ±5dgt / ±3%rdg ±5dvgt
  • Max. rating: 3 kVA max., 15 sec. cont. / -

Supplied Accessories

  • Kewtech EZYPAT Plus PAT Tester
  • Two rolls of Pass labels (x500)
  • Fail labels (x200)
  • PassWrap labels (x250)
  • PAT certificate pad
  • PAT register book
  • IEC adaptor kit
  • 110V appliance adaptor
  • 110V extension lead adaptor
  • 110V power adaptor
  • Microwave leakage detector
  • Microwave labels (x50)
  • Tuff Tag Pass labels (x250)
  • Kewtech KT103 socket tester
  • Kewtech KITBAG2 carry case

Kewtech EZYPAT Plus Kit C includes the Kewtech EZYPAT Plus PAT Tester in addition to a range of useful PAT accessories. The tester itself is one of the few battery-powered testers to perform 230V load & run testing and can also carry out regular PAT tests such as earth bond, insulation resistance, polarity and substitute leakage. It has pre-programmed automatic test sequences for Class I and Class II appliances and IEC/extension leads. Operation is carried out using simple push buttons and results are shown on screen alongside PASS/FAIL indications.

PAT testing accessories in Kewtech EZYPAT Plus Kit C allow the user to carry out more tests on a wide range of appliances. A full set of 110V adaptors is included for testing construction appliances and leads and there is power adaptor for performing powered tests. There is also an IEC adaptor set for leads used for IT and AV equipment. There are also a PAT certificate pad, PAT register books, indoor and outdoor PAT labels, a microwave leakage detector, a socket tester and a carry case.

For more information on the Kewtech EZYPAT Plus PAT Tester, please click here.

Kit Contents

  • Kewtech EZYPAT Plus PAT Tester
  • Two rolls of Pass labels (x500)
  • Fail labels (x200)
  • PassWrap labels (x250)
  • PAT certificate pad
  • PAT register book
  • IEC adaptor kit
  • 110V appliance adaptor
  • 110V extension lead adaptor
  • 110V power adaptor
  • Microwave leakage detector
  • Microwave labels (x50)
  • Tuff Tag Pass labels (x250)
  • Kewtech KT103 socket tester
  • Kewtech KITBAG2 carry case

  Kit A Kit B Kit C
Kewtech EZYPAT Plus PAT Tester
PASS labels x2 x2 x2
FAIL labels
PassWrap labels
Tuff Tag Pass Labels  
PAT certificate pad
PAT registerbook x1 x1 x2
IEC clover leaf adaptor    
IEC adaptor kit  
110V appliance adaptor  
110V extension lead adaptor  
110V power adaptor  
Kewtech KT103 Socket Tester
Microwave leakage detector
Microwave emission labels
Kewtech KITBAG2 carry case

Protective Conductor Resistance

  • Measuring range: 0.00 - 20.00 Ω (NULL value inc)*
  • Over-range indication: > 20.00 Ω
  • Resolution: 0.01Ω
  • Open-circuit voltage: 5 V ±0.4 V DC
  • Measuring current: 200 mA DC (nominal value)
  • Accuracy: ±3%rdg ±5dgt

Mains Voltage

  • Display range: 30 - 270 V
  • Hi/ Lo indication: < 30 V: No voltage indication; > 270 V: 270 V 
  • Resolution & Accuracy: 1 V & ±3%rdg ±5dgt

Insulation

  • Rated voltage: 250V; 500V
  • Measuring range: 0.00 - 20.00 MΩ
  • Over-range indication: > 20.00 MΩ
  • Resolution: 0.01 MΩ
  • No-load voltage: 250 V DC +20%, -0% 500 V DC +20%, -0%
  • Short-circuit current: 1.5 mA DC or less
  • Rated current: 1 -1.2 mA with a load of 0.25 MΩ 1 to 1.2 mA with a load of 0.5 MΩ
  • Accuracy: ±2%rdg±3dgt

Substitute Leakage

  • Measuring range: 0.10 - 12.00 mA rms
  • Over-range indication: > 12.00 mA
  • Resolution: 0.01mA
  • Open-circuit voltage/ Freq.: 30 V ±5 V rms / 50 Hz ±5%
  • Measuring current: 1.2 mA AC ±0.5 mA (when measuring 12.00 mA)
  • Accuracy: ±3%rdg±5dgt

Insulation Test between L and N

  • Open-circuit voltage: 4.5 V ±0.5 V DC
  • Criteria of judgement: 100 kΩ ±20 kΩ or less: LCD shows “<0.10 MΩ” and the measurement is halted.

Run Leakage (Item: Load current / Leakage current)

  • Mains voltage range: 100 - 253 V / 50 Hz
  • Measuring range: 0.10 - 13.00 A rms / 0.10 - 20.00 mA rms
  • Display range: 0.00 - 13.00 A / 0.00 - 20.00 mA
  • Over-range indication: > 13.00 A / > 20.00 mA
  • Resolution: 0.01A / 0.01mA
  • Accuracy: ±10%rdg ±5dgt / ±3%rdg ±5dvgt
  • Max. rating: 3 kVA max., 15 sec. cont. / -
  • Kewtech EZYPAT Plus PAT Tester
  • Two rolls of Pass labels (x500)
  • Fail labels (x200)
  • PassWrap labels (x250)
  • PAT certificate pad
  • PAT register book
  • IEC adaptor kit
  • 110V appliance adaptor
  • 110V extension lead adaptor
  • 110V power adaptor
  • Microwave leakage detector
  • Microwave labels (x50)
  • Tuff Tag Pass labels (x250)
  • Kewtech KT103 socket tester
  • Kewtech KITBAG2 carry case