COVID-19: Open for business - Click for more info.

FREE DELIVERY ON ORDERS OVER £150,
WITH NEXT-DAY OPTIONS ALSO AVAILABLE

Fluke 6500-2 PAT Testing Kit A

  • A complete set of PAT testing functions
  • Includes 110V adaptor kit, thus enabling PAT testing on construction equipment
  • Microwave leakage detector included alongside PASS, FAIL and microwave leakage labels

£1,099.00 EXC. VAT

IN STOCK

Description

The Fluke 6500-2 Portable Appliance Tester is a professional instrument designed to meet the needs of high volume PAT testers and electrical contractors.

Now featuring a full colour display, the Fluke 6500-2 takes over from the popular 6500 model, offering all the functionality of its popular predecessor with a range of additional benefits such as 250V insulation resistance testing, portable RCD testing and active 110V appliance testing (using Fluke adaptors).

The Fluke 6500-2 PAT Tester stores up to 1000 test results with simple data transfer to a PC and an additional USB port for connecting to an optional printer.

Weighing around 3kg, the Fluke 6500-2 is one of the lightest professional PAT testers on the market, ideal for extended safety testing of electrical equipment in a range of locations.

Fluke 6500-2 PAT Testing Kit A Includes:

  • Fluke 6500-2 PAT Tester (complete with test lead with detachable clip and probe, mains lead, USB stick, USB cable, instruction manual, calibration certificate and Fluke carry case)
  • 1000 Pass Labels
  • 200 Fail Labels
  • 250 PassWrap Labels
  • Fluke 110V Adaptor Kit
  • 110V Extension Lead Adaptor
  • 230V Extension Lead Adaptor
  • Microwave Leakage Detector
  • Microwave Emission Labels
  • IEC Adaptor Kit
  • TEK989 Socket Tester 

For more information on the Fluke 6500-2 Portable Appliance Tester please click here.

  Kit A Kit B Kit C Kit D Starter Kit
Fluke 6500-2 PAT Tester
SimplyPATs Version 7 Software    
Fluke 0702/PAT Software        
Barcode Scanner      
Fluke SP6000 Mini Printer        
Barcode ID Labels        
Fluke 110V Adaptor Kit  
IEC Adaptor Kit, 110V & 230V Extension Lead Adapter  
EXTL100 Extension Lead Adaptor        
1000 Pass Labels, 200 Fail Labels & 250 PassWrap Labels  
Pass 560R Labels        
Microwave Leakage Detector & Microwave Emission Labels  
TEK989 Socket Tester  

Specification

Power-on Test

  • The test indicates reversed L-N, missing PE, and measures the mains voltage and frequency.
  • Display Range : 90 V to 264 V
  • Accuracy at 50 Hz: ± (2% + 3 counts)
  • Resolution: 0.1 V
  • Input Impedance: > 1 MΩ // 2.2 nF
  • Maximum Input Mains Voltage: 264 V

Earth Bond Test (Rpe)

  • Display Range: 0 to 19.99 Ω
  • Accuracy (After Bond Test Zeroing): ± (5% + 4 counts)
  • Resolution: 0.01 Ω
  • Test Current: 200 mA AC -0% +40% into 1.99 Ω; 25 A AC ± 20% into 25 mΩ at 230 V
  • Open Circuit Voltage: > 4 V AC, < 24 V AC
  • Bond Test Zeroing: Can subtract up to 1.99 Ω

Insulation Test (Riso)

  • Display Range: 0 to 299 MΩ
  • Accuracy: ± (5% + 2 counts) from 0.1 to 300 MΩ
  • Resolution: 0.01 MΩ (0 to 19.99 MΩ) / 0.1 MΩ (20 to 199.9 MΩ) / 1 MΩ (200 to 299 MΩ)
  • Test Voltage: 500 V DC -0% + 25% at 500 kΩ load or 250 V dc -0 % +25 % at 250 kΩ load
  • Test Current: > 1 mA at 500 kΩ load, < 15 mA at 0 Ω
  • Auto Discharge Time: < 0.5 s for 1 μF
  • Max. Capacitive Load: Operational up to 1 μF

Touch Current Test

  • Display Range: 0 to 1.99 mA AC
  • Accuracy: ± (4% + 2 counts)
  • Resolution: 0.01 mA
  • Internal Resistance (via Probe): 2 kΩ
  • Measuring Method: Probe*

Substitute Leakage Current Test

  • Display Range: 0 to 19.99 mA AC
  • Accuracy: ± (2.5% + 3 counts)
  • Resolution: 0.01 mA
  • Test Voltage: 100 V AC ± 20%

Load/Leakage Test: Load Current

  • Display Range: 0 A to 13 A
  • Accuracy: ± (4% + 2 counts)
  • Resolution: 0.1 A*

Load/Leakage Test: Load Power

  • Display Range 230 V Mains: 0.0 VA to 3.2 kVA
  • Accuracy: ± (5 % + 3 counts)
  • Resolution: 1 VA (0 to 999 VA), 0.1 kVA (>1.0 kVA)*

Load/Leakage Test: Leakage Current

  • Display Range: 0 to 19.99 mA
  • Accuracy: ± (4% + 4 counts)
  • Resolution: 0.01 mA*

PELV Test

  • Accuracy at 50 Hz: ± (2% + 3 counts)
  • Overload Protection: 300 V rms
  • Warning Threshold: 25 V rms

RCD Test: Trip Current

  • Operational Error: ±10 %
  • Nominal: 30 mA
  • Accuracy: ±5 %

RCD Test: Trip Time

  • Standard Requirement: 61557 Part 6; tolerance of rated test current 0 % to +10 %
  • Operational Error: ±10 %
  • RCD Type: AC general-purpose 30 mA
  • Display Range: 310 ms
  • Resolution: 0.1 ms
  • Accuracy: 3 ms
  • Trip Time Limit at 100 % (30 mA): 300 ms
  • Trip Time Limit at 500 % (150 mA): 40 ms

*The appliance under test is energised at mains voltage.

Environmental

  • Operating Temperature: 0 to 40 °C
  • Relative Humidity: Non condensing < 10 °C / 95% from 10 to 30 °C / 75% from 30 to 40 °C

Safety

  • Safety Rating: Complies with EN61010-1 3rd edition / CAT II, 300 V, pol 2

General

  • Size: 200 mm (L) x 275 mm (W) x 114 mm (H)
  • Weight: 3.13 kg
  • Power Supply: 230 V +10 % -15 %, 50 Hz ±2 Hz or (6500-2 only: 110V +10 % -15 %,50 Hz ±2 Hz)
  • Power Consumption (Tester): 13 W typical (idle) / 60 W max. during 25A Bond test
  • Storage Temperature: -10 to 60 °C
  • Corrosion: 70 °C @ 95 % RH for 5 days max.
  • Operating Altitude: 0 up to 2000 m
  • Sealing: IP-40 (enclosure), IP-20 (connectors)
  • EMC: Complies with EN61326-1, portable
  • EMI Immunity: 3 V/m

Supplied Accessories

Fluke 6500-2 Kit A comes with:
  • Fluke 6500-2 PAT Tester (complete with test lead with detachable clip and probe, mains lead, USB stick, USB cable, instruction manual, calibration certificate and Fluke carry case)
  • 1000 Pass Labels
  • 200 Fail Labels
  • 250 PassWrap Labels
  • Fluke 110V Adaptor Kit
  • 110V Extension Lead Adaptor
  • 230V Extension Lead Adaptor
  • Microwave Leakage Detector
  • Microwave Emission Labels
  • IEC Adaptor Kit
  • TEK989 Socket Tester

The Fluke 6500-2 Portable Appliance Tester is a professional instrument designed to meet the needs of high volume PAT testers and electrical contractors.

Now featuring a full colour display, the Fluke 6500-2 takes over from the popular 6500 model, offering all the functionality of its popular predecessor with a range of additional benefits such as 250V insulation resistance testing, portable RCD testing and active 110V appliance testing (using Fluke adaptors).

The Fluke 6500-2 PAT Tester stores up to 1000 test results with simple data transfer to a PC and an additional USB port for connecting to an optional printer.

Weighing around 3kg, the Fluke 6500-2 is one of the lightest professional PAT testers on the market, ideal for extended safety testing of electrical equipment in a range of locations.

Fluke 6500-2 PAT Testing Kit A Includes:

  • Fluke 6500-2 PAT Tester (complete with test lead with detachable clip and probe, mains lead, USB stick, USB cable, instruction manual, calibration certificate and Fluke carry case)
  • 1000 Pass Labels
  • 200 Fail Labels
  • 250 PassWrap Labels
  • Fluke 110V Adaptor Kit
  • 110V Extension Lead Adaptor
  • 230V Extension Lead Adaptor
  • Microwave Leakage Detector
  • Microwave Emission Labels
  • IEC Adaptor Kit
  • TEK989 Socket Tester 

For more information on the Fluke 6500-2 Portable Appliance Tester please click here.

  Kit A Kit B Kit C Kit D Starter Kit
Fluke 6500-2 PAT Tester
SimplyPATs Version 7 Software    
Fluke 0702/PAT Software        
Barcode Scanner      
Fluke SP6000 Mini Printer        
Barcode ID Labels        
Fluke 110V Adaptor Kit  
IEC Adaptor Kit, 110V & 230V Extension Lead Adapter  
EXTL100 Extension Lead Adaptor        
1000 Pass Labels, 200 Fail Labels & 250 PassWrap Labels  
Pass 560R Labels        
Microwave Leakage Detector & Microwave Emission Labels  
TEK989 Socket Tester  

Power-on Test

  • The test indicates reversed L-N, missing PE, and measures the mains voltage and frequency.
  • Display Range : 90 V to 264 V
  • Accuracy at 50 Hz: ± (2% + 3 counts)
  • Resolution: 0.1 V
  • Input Impedance: > 1 MΩ // 2.2 nF
  • Maximum Input Mains Voltage: 264 V

Earth Bond Test (Rpe)

  • Display Range: 0 to 19.99 Ω
  • Accuracy (After Bond Test Zeroing): ± (5% + 4 counts)
  • Resolution: 0.01 Ω
  • Test Current: 200 mA AC -0% +40% into 1.99 Ω; 25 A AC ± 20% into 25 mΩ at 230 V
  • Open Circuit Voltage: > 4 V AC, < 24 V AC
  • Bond Test Zeroing: Can subtract up to 1.99 Ω

Insulation Test (Riso)

  • Display Range: 0 to 299 MΩ
  • Accuracy: ± (5% + 2 counts) from 0.1 to 300 MΩ
  • Resolution: 0.01 MΩ (0 to 19.99 MΩ) / 0.1 MΩ (20 to 199.9 MΩ) / 1 MΩ (200 to 299 MΩ)
  • Test Voltage: 500 V DC -0% + 25% at 500 kΩ load or 250 V dc -0 % +25 % at 250 kΩ load
  • Test Current: > 1 mA at 500 kΩ load, < 15 mA at 0 Ω
  • Auto Discharge Time: < 0.5 s for 1 μF
  • Max. Capacitive Load: Operational up to 1 μF

Touch Current Test

  • Display Range: 0 to 1.99 mA AC
  • Accuracy: ± (4% + 2 counts)
  • Resolution: 0.01 mA
  • Internal Resistance (via Probe): 2 kΩ
  • Measuring Method: Probe*

Substitute Leakage Current Test

  • Display Range: 0 to 19.99 mA AC
  • Accuracy: ± (2.5% + 3 counts)
  • Resolution: 0.01 mA
  • Test Voltage: 100 V AC ± 20%

Load/Leakage Test: Load Current

  • Display Range: 0 A to 13 A
  • Accuracy: ± (4% + 2 counts)
  • Resolution: 0.1 A*

Load/Leakage Test: Load Power

  • Display Range 230 V Mains: 0.0 VA to 3.2 kVA
  • Accuracy: ± (5 % + 3 counts)
  • Resolution: 1 VA (0 to 999 VA), 0.1 kVA (>1.0 kVA)*

Load/Leakage Test: Leakage Current

  • Display Range: 0 to 19.99 mA
  • Accuracy: ± (4% + 4 counts)
  • Resolution: 0.01 mA*

PELV Test

  • Accuracy at 50 Hz: ± (2% + 3 counts)
  • Overload Protection: 300 V rms
  • Warning Threshold: 25 V rms

RCD Test: Trip Current

  • Operational Error: ±10 %
  • Nominal: 30 mA
  • Accuracy: ±5 %

RCD Test: Trip Time

  • Standard Requirement: 61557 Part 6; tolerance of rated test current 0 % to +10 %
  • Operational Error: ±10 %
  • RCD Type: AC general-purpose 30 mA
  • Display Range: 310 ms
  • Resolution: 0.1 ms
  • Accuracy: 3 ms
  • Trip Time Limit at 100 % (30 mA): 300 ms
  • Trip Time Limit at 500 % (150 mA): 40 ms

*The appliance under test is energised at mains voltage.

Environmental

  • Operating Temperature: 0 to 40 °C
  • Relative Humidity: Non condensing < 10 °C / 95% from 10 to 30 °C / 75% from 30 to 40 °C

Safety

  • Safety Rating: Complies with EN61010-1 3rd edition / CAT II, 300 V, pol 2

General

  • Size: 200 mm (L) x 275 mm (W) x 114 mm (H)
  • Weight: 3.13 kg
  • Power Supply: 230 V +10 % -15 %, 50 Hz ±2 Hz or (6500-2 only: 110V +10 % -15 %,50 Hz ±2 Hz)
  • Power Consumption (Tester): 13 W typical (idle) / 60 W max. during 25A Bond test
  • Storage Temperature: -10 to 60 °C
  • Corrosion: 70 °C @ 95 % RH for 5 days max.
  • Operating Altitude: 0 up to 2000 m
  • Sealing: IP-40 (enclosure), IP-20 (connectors)
  • EMC: Complies with EN61326-1, portable
  • EMI Immunity: 3 V/m
Fluke 6500-2 Kit A comes with:
  • Fluke 6500-2 PAT Tester (complete with test lead with detachable clip and probe, mains lead, USB stick, USB cable, instruction manual, calibration certificate and Fluke carry case)
  • 1000 Pass Labels
  • 200 Fail Labels
  • 250 PassWrap Labels
  • Fluke 110V Adaptor Kit
  • 110V Extension Lead Adaptor
  • 230V Extension Lead Adaptor
  • Microwave Leakage Detector
  • Microwave Emission Labels
  • IEC Adaptor Kit
  • TEK989 Socket Tester