COVID-19: Open for business - Click for more info.

FREE DELIVERY ON ORDERS OVER £150,
WITH NEXT-DAY OPTIONS ALSO AVAILABLE

Seaward Primetest 250 Plus PATMobile App and Mobile Bundle

  • Extensive range of electrical testing in line with IET 5th edition testing
  • Record and share data with the Seaward PATMobile App
  • Test n Tag Pro Bluetooth label printer compatible

£945.00 EXC. VAT

IN STOCK

Description

Seaward Primetest 250 Plus PATMobile App and Mobile Bundle

The Seaward Primetest 250+ PATMobile App and Mobile Bundle allows users to digitally store, report and produce labels using the Primetest 250+ and PATMobile App

The Primetest 250 Plus is a battery powered and downloadable PAT tester with testing capabilities that fully satisfy the latest edition of the IET Code of practice. The Primetest has many functions such as selectable Pass/Fail values for earth continuity (0.1, 0.2, 0.3Ω), Long lead test, new test for class 1 equipment with no exposed parts, test sequence for class 2 FW equipment and Pass/Fail limit of 5mA for all earth leakage tests.

The Primetest 250 Plus is a simple yet versatile offering many tests normally only found on more expensive packages. The Primetest 250+ will test Earth Continuity and insulation at 250V and 500V, IEC lead tests, touch current along with mains powered tests such as RCD Trip Time testing (using the main lead included), Earth Leakage and Protective Conductive current testing. Another benefit is the 250+’s ability to run mains operated tests on 3-Phase appliances using optional Seaward TPA 3-Phase Adaptors.

    Seaward PATMobile Kit

    The Seaward PATMobile Kit is an accessory bundle created by Seaward to allow users who are PAT testing the ability to create and store Digital measurement results. Labels can also be generated when used alongside the Seaward PATMobile App. Included in the kit is the Seaward Test n Tag Pro Bluetooth label printer, Test n Tag label rolls (x 4), IEC Cloverleaf adaptor, PrimeTest Checkbox, carry bag and an online Guide to PAT Course.

    Seaward PATmobile App

    Available for free on Google Play or Apple App Store, this extremely useful app can create professional PDF reports, allow users to share them with customers and display PAT records on your personal smartphone. Due to the straightforward interface it's incredibly easy to store PAT results, scan barcodes or print labels with the addition of the Seaward Test n Tag Pro Bluetooth Printer.

    The PATMobile App boasts a number of useful features:

    • Simple to use interface
    • Customisable
    • Search and filter through recorded results
    • Incorporated risk assessment and resistance calculator
    • Auto-incrementing asset ID
    • Capture and attach images to reports
    • Printing via Bluetooth connection
    • Export PDF reports or CSV spreadsheets
    • Dashboard feature tracks out of date items

    Seaward Test n' Tag Pro Serial and Bluetooth Printer 339A980

    The Seaward Test n' Tag Pro Serial and Bluetooth Printer is designed to enable users to print labels quickly and of high quality.

    The Pro printer features a high speed processor, extensive memory and records test information including asset number, username, test status, barcode, test date and next date allowing peace of mind for any busy contractor looking to cut time testing and recording. 

    IEC Plug - Cloverleaf Adaptor

    This IEC (kettle lead) to Clover Lead (mickey mouse) is ideal for adapting leads normally found on projectors & laptop chargers and will suit any PAT Testers tool kit.

    • Rating: 10A @ 125V / 2.5A @ 250V
    • Insulation Resistance: 100MΩ
    • Dilectric Voltage: 2000V/sec
    • Plug Adapter IEC60320 C6 Plug to IEC60320 C13
    • Adapt an IEC 320 C14 Male Plug (10 Amp 250 Volt shroud) to fit into an IEC C5 outlet.

    Seaward Primetest PAT Tester Checkbox

    The Seaward Primetest PAT Tester Checkbox is designed to test the accuracy of Seaward PAT testers like the Primetest 250+ in between annual calibrations. It is capable of checking the testers’ auto test sequences for Class I appliances in addition to Class II appliances. The checkbox shows that the testers are capable of detecting fail results whilst a simple test with the supplied IEC lead will show that they can detect pass results.

    • Simple to use interface
    • Customisable
    • Search and filter through recorded results
    • Incorporated risk assessment and resistance calculator
    • Auto-incrementing asset ID
    • Capture and attach images to reports
    • Printing via Bluetooth connection
    • Export PDF reports or CSV spreadsheets
    • Dashboard feature tracks out of date items

    Key Features

    • Portable ergonomic design for hand held portable use
    • Comprehensive range of electrical tests
    • Internal data storage - stores up to 999 appliance records
    • Seaward cataloguing software included for report production
    • Single save and download function, date and time stamped results
    • Test 3 phase appliances with additional adaptors
    • Plug and print- easy label printing with no set-up required
    • Patent pending low current earth continuity tests guarantees accurate measurements

    Specifications

    Earth Continuity

    • Output Current: 200mA minimum into 2Ω
    • Test Voltage (o/c): 9V DC nominal
    • Test Duration (Class I Test): 2s nominal
    • Display Range: 0.01Ω to 19.99Ω
    • Pass Value (Class I Test): 0.1/0.2/0.3Ω

    Insulation Resistance

    • Test Voltage: 250/500V DC @1mA nominal, <2mA (s/c)
    • Test Current: <2mA (s/c)
    • Test Duration (Class I or II): 2s
    • Display Range: 0.01MΩ to 19.99MΩ
    • Pass Value:
      - Class I: 1.0MΩ
      - Class II: 2.0MΩ

    Substitute Leakage

    • Test Voltage: 40V Nominal AC 50Hz Open Circuit
    • Test Duration: 2s
    • Display Range: 0.1mA to 19.99mA
    • Pass Value: 5.0mA

    IEC Lead Test

    • Test Voltage: 5V DC Nominal
    • Test Duration: Time for Test (2s max)
    • Test: Live/Neutral Checks for o/c, s/c and crossed

    Protective Conductor Current

    • Test Voltage: Supply voltage, max current 13A
    • Test Duration: 120s Maximum
    • Display Range: 0.15mA to 19.99mA
    • Pass Value: 5.0mA

    Touch Current

    • Test Voltage: Supply voltage, max current 13A
    • Test Duration: 120s maximum
    • Display Range: 0.10mA to 3.50mA
    • Pass Value: 5.0mA

    3 Phase Differential Leakage Current (Requires 3 phase adaptor accessory)

    • Test Voltage: 3 phase supply voltage
    • Test Duration: Continuous measurement
    • Display Range: 0.10mA to 9.99mA
    • Pass Value: 5.0mA

    RCD Trip Time

    • RCD Type: Plugtop and fixed installation
    • Test Voltage; Mains supply voltage
    • Test Current: 30mA/150mA rms sinusoidal
    • Test Current Phase: 0/180° auto switched on alternate tests
    • Measuring Range: 0ms to 500ms
    • Pass Value: 200ms

    Power Socket Check

    • Input Voltage Range: 225-254V AC max current 13A UK
    • Indicates configuration of voltage potential:
      - Line to earth
      - Line to neutral
      - Neutral to earth

    General

    • Dimensions: 265mm x 105mm x 52mm (h x w x d)
    • Weight: 800g
    • Memory Size: 999 Test Records
    • Power Source: 6 x AA Batteries


    Supplied Accessories

    • Seaward Primetest 250+ PAT Tester 5th Edition compliant
    • Seaward 0.5m extension lead adaptor
    • Seaward Earth Lead with probe and clip
    • Seaward mains lead
    • 6 x AA batteries
    • USB download lead
    • Seaward carry case
    • Seaward operating instructions
    • Test n Tag Pro bluetooth label printer
    • 4 x Test n Tag label rolls
    • IEC Cloverleaf adaptor
    • PrimeTest Checkbox
    • Online Guide to PAT course

    Seaward Primetest 250 Plus PATMobile App and Mobile Bundle

    The Seaward Primetest 250+ PATMobile App and Mobile Bundle allows users to digitally store, report and produce labels using the Primetest 250+ and PATMobile App

    The Primetest 250 Plus is a battery powered and downloadable PAT tester with testing capabilities that fully satisfy the latest edition of the IET Code of practice. The Primetest has many functions such as selectable Pass/Fail values for earth continuity (0.1, 0.2, 0.3Ω), Long lead test, new test for class 1 equipment with no exposed parts, test sequence for class 2 FW equipment and Pass/Fail limit of 5mA for all earth leakage tests.

    The Primetest 250 Plus is a simple yet versatile offering many tests normally only found on more expensive packages. The Primetest 250+ will test Earth Continuity and insulation at 250V and 500V, IEC lead tests, touch current along with mains powered tests such as RCD Trip Time testing (using the main lead included), Earth Leakage and Protective Conductive current testing. Another benefit is the 250+’s ability to run mains operated tests on 3-Phase appliances using optional Seaward TPA 3-Phase Adaptors.

      Seaward PATMobile Kit

      The Seaward PATMobile Kit is an accessory bundle created by Seaward to allow users who are PAT testing the ability to create and store Digital measurement results. Labels can also be generated when used alongside the Seaward PATMobile App. Included in the kit is the Seaward Test n Tag Pro Bluetooth label printer, Test n Tag label rolls (x 4), IEC Cloverleaf adaptor, PrimeTest Checkbox, carry bag and an online Guide to PAT Course.

      Seaward PATmobile App

      Available for free on Google Play or Apple App Store, this extremely useful app can create professional PDF reports, allow users to share them with customers and display PAT records on your personal smartphone. Due to the straightforward interface it's incredibly easy to store PAT results, scan barcodes or print labels with the addition of the Seaward Test n Tag Pro Bluetooth Printer.

      The PATMobile App boasts a number of useful features:

      • Simple to use interface
      • Customisable
      • Search and filter through recorded results
      • Incorporated risk assessment and resistance calculator
      • Auto-incrementing asset ID
      • Capture and attach images to reports
      • Printing via Bluetooth connection
      • Export PDF reports or CSV spreadsheets
      • Dashboard feature tracks out of date items

      Seaward Test n' Tag Pro Serial and Bluetooth Printer 339A980

      The Seaward Test n' Tag Pro Serial and Bluetooth Printer is designed to enable users to print labels quickly and of high quality.

      The Pro printer features a high speed processor, extensive memory and records test information including asset number, username, test status, barcode, test date and next date allowing peace of mind for any busy contractor looking to cut time testing and recording. 

      IEC Plug - Cloverleaf Adaptor

      This IEC (kettle lead) to Clover Lead (mickey mouse) is ideal for adapting leads normally found on projectors & laptop chargers and will suit any PAT Testers tool kit.

      • Rating: 10A @ 125V / 2.5A @ 250V
      • Insulation Resistance: 100MΩ
      • Dilectric Voltage: 2000V/sec
      • Plug Adapter IEC60320 C6 Plug to IEC60320 C13
      • Adapt an IEC 320 C14 Male Plug (10 Amp 250 Volt shroud) to fit into an IEC C5 outlet.

      Seaward Primetest PAT Tester Checkbox

      The Seaward Primetest PAT Tester Checkbox is designed to test the accuracy of Seaward PAT testers like the Primetest 250+ in between annual calibrations. It is capable of checking the testers’ auto test sequences for Class I appliances in addition to Class II appliances. The checkbox shows that the testers are capable of detecting fail results whilst a simple test with the supplied IEC lead will show that they can detect pass results.

      • Simple to use interface
      • Customisable
      • Search and filter through recorded results
      • Incorporated risk assessment and resistance calculator
      • Auto-incrementing asset ID
      • Capture and attach images to reports
      • Printing via Bluetooth connection
      • Export PDF reports or CSV spreadsheets
      • Dashboard feature tracks out of date items

      Key Features

      • Portable ergonomic design for hand held portable use
      • Comprehensive range of electrical tests
      • Internal data storage - stores up to 999 appliance records
      • Seaward cataloguing software included for report production
      • Single save and download function, date and time stamped results
      • Test 3 phase appliances with additional adaptors
      • Plug and print- easy label printing with no set-up required
      • Patent pending low current earth continuity tests guarantees accurate measurements

      Earth Continuity

      • Output Current: 200mA minimum into 2Ω
      • Test Voltage (o/c): 9V DC nominal
      • Test Duration (Class I Test): 2s nominal
      • Display Range: 0.01Ω to 19.99Ω
      • Pass Value (Class I Test): 0.1/0.2/0.3Ω

      Insulation Resistance

      • Test Voltage: 250/500V DC @1mA nominal, <2mA (s/c)
      • Test Current: <2mA (s/c)
      • Test Duration (Class I or II): 2s
      • Display Range: 0.01MΩ to 19.99MΩ
      • Pass Value:
        - Class I: 1.0MΩ
        - Class II: 2.0MΩ

      Substitute Leakage

      • Test Voltage: 40V Nominal AC 50Hz Open Circuit
      • Test Duration: 2s
      • Display Range: 0.1mA to 19.99mA
      • Pass Value: 5.0mA

      IEC Lead Test

      • Test Voltage: 5V DC Nominal
      • Test Duration: Time for Test (2s max)
      • Test: Live/Neutral Checks for o/c, s/c and crossed

      Protective Conductor Current

      • Test Voltage: Supply voltage, max current 13A
      • Test Duration: 120s Maximum
      • Display Range: 0.15mA to 19.99mA
      • Pass Value: 5.0mA

      Touch Current

      • Test Voltage: Supply voltage, max current 13A
      • Test Duration: 120s maximum
      • Display Range: 0.10mA to 3.50mA
      • Pass Value: 5.0mA

      3 Phase Differential Leakage Current (Requires 3 phase adaptor accessory)

      • Test Voltage: 3 phase supply voltage
      • Test Duration: Continuous measurement
      • Display Range: 0.10mA to 9.99mA
      • Pass Value: 5.0mA

      RCD Trip Time

      • RCD Type: Plugtop and fixed installation
      • Test Voltage; Mains supply voltage
      • Test Current: 30mA/150mA rms sinusoidal
      • Test Current Phase: 0/180° auto switched on alternate tests
      • Measuring Range: 0ms to 500ms
      • Pass Value: 200ms

      Power Socket Check

      • Input Voltage Range: 225-254V AC max current 13A UK
      • Indicates configuration of voltage potential:
        - Line to earth
        - Line to neutral
        - Neutral to earth

      General

      • Dimensions: 265mm x 105mm x 52mm (h x w x d)
      • Weight: 800g
      • Memory Size: 999 Test Records
      • Power Source: 6 x AA Batteries


      • Seaward Primetest 250+ PAT Tester 5th Edition compliant
      • Seaward 0.5m extension lead adaptor
      • Seaward Earth Lead with probe and clip
      • Seaward mains lead
      • 6 x AA batteries
      • USB download lead
      • Seaward carry case
      • Seaward operating instructions
      • Test n Tag Pro bluetooth label printer
      • 4 x Test n Tag label rolls
      • IEC Cloverleaf adaptor
      • PrimeTest Checkbox
      • Online Guide to PAT course