COVID-19: Open for business - Click for more info.

FREE DELIVERY ON ORDERS OVER £150,
WITH NEXT-DAY OPTIONS ALSO AVAILABLE

Megger PAT150R Rechargable PAT Tester

  • Meets all the latest regulation surrounding PAT testing
  • PASS/FAIL indication shown on screen according to customisable limits
  • Rechargeable batteries power the tester independently

£575.00 EXC. VAT

IN STOCK

Description

Providing user-friendly, reliable and efficient safety testing for portable and fixed electrical equipment, the Megger PAT150R Rechargeable Portable Appliance Tester is ideal for use in most environments, including offices, shops and business units. 

Offering additional tests for testing portable RCDs as well as test groups for Class I, Class II and extension/power leads, the Megger PAT150R also offers insulation testing at either 500V or 250V and substitute leakage testing.

Giving users a wealth of options, the Megger PAT150R also provides tests for Continuity, Insulation, mains powered leakage testing and SELV measurements.

It also offers adjustable PASS limits and user-configurable test durations, as well as allowing users to null Bond lead resistance to reduce measurement errors, making it an incredibly useful PAT Tester.

Live circuit measurement is also available for testing the mains supply and socket polarity or electrical circuit voltage to 300V (AC). 

Manufactured in rubber armour and fitted with toughened "Gorilla" glass, the Megger PAT150R is extremely durable and the ability to recharge the tester ensures you won't be caught short on the job.

Megger PAT150R PAT Tester Key Features

  • Easy to use pass fail indication & measurement with adjustable PASS limits
  • Complies fully with the latest version of the IET Code of Practice 
  • Rechargeable, handheld design
  • Includes 250V Insulation and Leakage testing for safe IT testing and surge protected devices
  • Test groups for Class I, Class II, Extension/Power leads and PRCDs
  • 10mA and 30mA Portable RCD lead testing options
  • Substitute and Mains powered leakage testing
  • Protective outer casing with front cover and toughened glass
  PAT120 PAT150 PAT150R
Earth Bond Continuity Test
Insulation Test (250V, 500V)
Substitute Leakage Test
Earth Leakage Test  
Touch Current Test  
Portable RCD Testing  
Polarity Testing  
Live Circuit Measurement  
PASS/FAIL Indication
Battery Operated
Rechargeable    

Specification

Environmental Conditions

  • Operating ambient: 20°C
  • Humidity: Nominal humidity

Continuity Test

  • Test voltage: Compliance Voltage: +4V dc, –0 % /+10 % (open circuit)
  • Test current: Bi-directional +200mA, -0% + 50mA (into 2Ω load)
  • Continuity accuracy: Resistance: ± 5% ± 3 digits (0 to 19.99 Ω)
  • Resistance resolution: 10 mΩ
  • Display range: 0.01 to 19.99Ω
  • Continuity test nulling: up to 9.99 Ω
  • Test time: User selectable from 2 sec to 20 sec or selected during test to 180sec

Insulation Test

  • Insulation test: 250V dc –0 % /+25 % open circuit, 500V dc –0 % /+25 % open circuit, ≥ 500V 0% dc across 0.5 MΩ load
  • Short circuit/charge current: < 2mA dc
  • Insulation accuracy: ±3% ±10 digits (0 to 19.99 MΩ)
  • Resolution: 0.01 MΩ
  • Display range: 0.10 MΩ to 99.99 MΩ
  • Test duration: User selectable from 2 sec to 20 sec or selected during test to 180sec

Substitute Leakage Test

  • Leakage current: Accuracy ± 5% ± 3 digits
  • Test frequency: Nominal mains frequency 50Hz
  • Test voltage: < 50V ac
  • Resolution: 0.01mA
  • Display range: 0.10 to 19.99mA
  • Test duration: User selectable from 2 sec to 5 seconds
  • Reading corrected to 230V ac.

Touch Current Test

  • Test voltage: Nominal mains 230 V ac
  • Test frequency: Nominal mains 50 Hz
  • Test accuracy: ± 5% ± 3 digits
  • Resolution: 0.01 mA
  • Display range: 0.10 to 3.99 mA
  • Test duration: User selectable from 2 sec to 5 sec

SELV Device Test

  • Test voltage: 0 to 300 V ac
  • Measurement accuracy: ± 3% ± 3 digits
  • Resolution: 0.1 V ac
  • Display range: 0.1 to 300 V ac

Extension Lead Test

Test includes Insulation and Bond tests.

  • Test voltage: 5V
  • Polarity: Lead OK, Live/neutral shorted, Live/neutral reversed, Live/neutral open circuit

Portable RCD Test

  • Test voltage: Nominal mains 230 V
  • Test frequency: 50Hz
  • Test current accuracy: +2% to +8% (1 x I, 5 x I)
  • Trip time accuracy: ±1% ± 1ms
  • Trip time resolution: 0.01ms
  • Display range: 0 to 200ms (1 x I), 0 to 40ms (5 x I)

Mains Supply Test

  • Frequency measurement range: 50 Hz
  • Test voltage: 40 to 300V ac
  • Accuracy: ± 3% ± 3 digits
  • Resolution: 0.1Vac
  • Display range: 40 to 300V ac

Circuit Test

Carried out automatically, not available to user.

  • Test voltage: 5V
  • Test frequency: Nominal Mains 50 Hz
  • Test current: < 100mA short circuit

Safety

  • Instrument designed to IEC 61010-1: 2012
  • Test leads designed to IEC 61010-031: 2005
  • 300 volts to Earth Category II
  • Mains fuse protection to 250 volts rms ac

EMC

  • Design to meet IEC 61326-1: 2006 and IEC 61326-2-2: 2005.

Environmental

  • Operating temperature range: 0°C to +40°C
  • Storage temperature range: -20°C to +60°C
  • Humidity: 90%RH @ +10°C +30°C, 75%RH @ +30°C to +40°C
  • Maximum altitude: 2,000m to full safety spec.
  • IP rating: IP40 (with front cover closed)

General

  • Battery: Supply voltage, 12 Vdc (Alkaline AA LR6), 9.6 Vdc (NiMH AA LR6)
  • Weight (PAT150 Only): 1300g
  • Weight (Shipping): 2795g / 2975g for PAT150R
  • Dimensions: 203 x 148 x 78mm
  • Megger Part Number: 1003-064 / 1003-428 (rechargable model)

Supplied Accessories

The Megger PAT150R Rechargeable PAT Tester comes with:

  • Megger PAT150R (1003-428)
  • Continuity/earth bond test lead Probe & Croc Clip
  • Extension Lead Adaptor
  • AC Charger Adaptor for Megger PAT150R only
  • Mains Supply Cord
  • SELV/mains voltage test lead Red
  • Calibration certificate
  • 8 x AA Batteries, 8 x rechargeable batteries for Megger PAT150R
  • Instructions
  • Carry Case

Kit Options

The Megger PAT150R PAT Tester is available in a range of kits:

Kit A Kit B Kit C
Megger PAT150R PAT Tester
SimplyPATs Version 7 Manual Software
2 x 500 Pass Labels
200 Fail Labels
250 PassWrap Labels
PAT Register Book
PAT Certificate Pad
IEC Cloverleaf Adaptor
IEC Adaptor Kit
110V Appliance Adaptor
110V Extension Lead Adaptor
Microwave Leakage Detector
150 Microwave Emission Labels
Megger MST210 Socket Tester

Videos

 

Providing user-friendly, reliable and efficient safety testing for portable and fixed electrical equipment, the Megger PAT150R Rechargeable Portable Appliance Tester is ideal for use in most environments, including offices, shops and business units. 

Offering additional tests for testing portable RCDs as well as test groups for Class I, Class II and extension/power leads, the Megger PAT150R also offers insulation testing at either 500V or 250V and substitute leakage testing.

Giving users a wealth of options, the Megger PAT150R also provides tests for Continuity, Insulation, mains powered leakage testing and SELV measurements.

It also offers adjustable PASS limits and user-configurable test durations, as well as allowing users to null Bond lead resistance to reduce measurement errors, making it an incredibly useful PAT Tester.

Live circuit measurement is also available for testing the mains supply and socket polarity or electrical circuit voltage to 300V (AC). 

Manufactured in rubber armour and fitted with toughened "Gorilla" glass, the Megger PAT150R is extremely durable and the ability to recharge the tester ensures you won't be caught short on the job.

Megger PAT150R PAT Tester Key Features

  • Easy to use pass fail indication & measurement with adjustable PASS limits
  • Complies fully with the latest version of the IET Code of Practice 
  • Rechargeable, handheld design
  • Includes 250V Insulation and Leakage testing for safe IT testing and surge protected devices
  • Test groups for Class I, Class II, Extension/Power leads and PRCDs
  • 10mA and 30mA Portable RCD lead testing options
  • Substitute and Mains powered leakage testing
  • Protective outer casing with front cover and toughened glass
  PAT120 PAT150 PAT150R
Earth Bond Continuity Test
Insulation Test (250V, 500V)
Substitute Leakage Test
Earth Leakage Test  
Touch Current Test  
Portable RCD Testing  
Polarity Testing  
Live Circuit Measurement  
PASS/FAIL Indication
Battery Operated
Rechargeable    

Environmental Conditions

  • Operating ambient: 20°C
  • Humidity: Nominal humidity

Continuity Test

  • Test voltage: Compliance Voltage: +4V dc, –0 % /+10 % (open circuit)
  • Test current: Bi-directional +200mA, -0% + 50mA (into 2Ω load)
  • Continuity accuracy: Resistance: ± 5% ± 3 digits (0 to 19.99 Ω)
  • Resistance resolution: 10 mΩ
  • Display range: 0.01 to 19.99Ω
  • Continuity test nulling: up to 9.99 Ω
  • Test time: User selectable from 2 sec to 20 sec or selected during test to 180sec

Insulation Test

  • Insulation test: 250V dc –0 % /+25 % open circuit, 500V dc –0 % /+25 % open circuit, ≥ 500V 0% dc across 0.5 MΩ load
  • Short circuit/charge current: < 2mA dc
  • Insulation accuracy: ±3% ±10 digits (0 to 19.99 MΩ)
  • Resolution: 0.01 MΩ
  • Display range: 0.10 MΩ to 99.99 MΩ
  • Test duration: User selectable from 2 sec to 20 sec or selected during test to 180sec

Substitute Leakage Test

  • Leakage current: Accuracy ± 5% ± 3 digits
  • Test frequency: Nominal mains frequency 50Hz
  • Test voltage: < 50V ac
  • Resolution: 0.01mA
  • Display range: 0.10 to 19.99mA
  • Test duration: User selectable from 2 sec to 5 seconds
  • Reading corrected to 230V ac.

Touch Current Test

  • Test voltage: Nominal mains 230 V ac
  • Test frequency: Nominal mains 50 Hz
  • Test accuracy: ± 5% ± 3 digits
  • Resolution: 0.01 mA
  • Display range: 0.10 to 3.99 mA
  • Test duration: User selectable from 2 sec to 5 sec

SELV Device Test

  • Test voltage: 0 to 300 V ac
  • Measurement accuracy: ± 3% ± 3 digits
  • Resolution: 0.1 V ac
  • Display range: 0.1 to 300 V ac

Extension Lead Test

Test includes Insulation and Bond tests.

  • Test voltage: 5V
  • Polarity: Lead OK, Live/neutral shorted, Live/neutral reversed, Live/neutral open circuit

Portable RCD Test

  • Test voltage: Nominal mains 230 V
  • Test frequency: 50Hz
  • Test current accuracy: +2% to +8% (1 x I, 5 x I)
  • Trip time accuracy: ±1% ± 1ms
  • Trip time resolution: 0.01ms
  • Display range: 0 to 200ms (1 x I), 0 to 40ms (5 x I)

Mains Supply Test

  • Frequency measurement range: 50 Hz
  • Test voltage: 40 to 300V ac
  • Accuracy: ± 3% ± 3 digits
  • Resolution: 0.1Vac
  • Display range: 40 to 300V ac

Circuit Test

Carried out automatically, not available to user.

  • Test voltage: 5V
  • Test frequency: Nominal Mains 50 Hz
  • Test current: < 100mA short circuit

Safety

  • Instrument designed to IEC 61010-1: 2012
  • Test leads designed to IEC 61010-031: 2005
  • 300 volts to Earth Category II
  • Mains fuse protection to 250 volts rms ac

EMC

  • Design to meet IEC 61326-1: 2006 and IEC 61326-2-2: 2005.

Environmental

  • Operating temperature range: 0°C to +40°C
  • Storage temperature range: -20°C to +60°C
  • Humidity: 90%RH @ +10°C +30°C, 75%RH @ +30°C to +40°C
  • Maximum altitude: 2,000m to full safety spec.
  • IP rating: IP40 (with front cover closed)

General

  • Battery: Supply voltage, 12 Vdc (Alkaline AA LR6), 9.6 Vdc (NiMH AA LR6)
  • Weight (PAT150 Only): 1300g
  • Weight (Shipping): 2795g / 2975g for PAT150R
  • Dimensions: 203 x 148 x 78mm
  • Megger Part Number: 1003-064 / 1003-428 (rechargable model)

The Megger PAT150R Rechargeable PAT Tester comes with:

  • Megger PAT150R (1003-428)
  • Continuity/earth bond test lead Probe & Croc Clip
  • Extension Lead Adaptor
  • AC Charger Adaptor for Megger PAT150R only
  • Mains Supply Cord
  • SELV/mains voltage test lead Red
  • Calibration certificate
  • 8 x AA Batteries, 8 x rechargeable batteries for Megger PAT150R
  • Instructions
  • Carry Case

The Megger PAT150R PAT Tester is available in a range of kits:

Kit A Kit B Kit C
Megger PAT150R PAT Tester
SimplyPATs Version 7 Manual Software
2 x 500 Pass Labels
200 Fail Labels
250 PassWrap Labels
PAT Register Book
PAT Certificate Pad
IEC Cloverleaf Adaptor
IEC Adaptor Kit
110V Appliance Adaptor
110V Extension Lead Adaptor
Microwave Leakage Detector
150 Microwave Emission Labels
Megger MST210 Socket Tester