Megger PAT150R Rechargable PAT Tester
- Meets all the latest regulation surrounding PAT testing
- PASS/FAIL indication shown on screen according to customisable limits
- Rechargeable batteries power the tester independently
Providing user-friendly, reliable and efficient safety testing for portable and fixed electrical equipment, the Megger PAT150R Rechargeable Portable Appliance Tester is ideal for use in most environments, including offices, shops and business units.
Offering additional tests for testing portable RCDs as well as test groups for Class I, Class II and extension/power leads, the Megger PAT150R also offers insulation testing at either 500V or 250V and substitute leakage testing.
Giving users a wealth of options, the Megger PAT150R also provides tests for Continuity, Insulation, mains powered leakage testing and SELV measurements.
It also offers adjustable PASS limits and user-configurable test durations, as well as allowing users to null Bond lead resistance to reduce measurement errors, making it an incredibly useful PAT Tester.
Live circuit measurement is also available for testing the mains supply and socket polarity or electrical circuit voltage to 300V (AC).
Manufactured in rubber armour and fitted with toughened "Gorilla" glass, the Megger PAT150R is extremely durable and the ability to recharge the tester ensures you won't be caught short on the job.
Megger PAT150R PAT Tester Key Features
- Easy to use pass fail indication & measurement with adjustable PASS limits
- Complies fully with the latest version of the IET Code of Practice
- Rechargeable, handheld design
- Includes 250V Insulation and Leakage testing for safe IT testing and surge protected devices
- Test groups for Class I, Class II, Extension/Power leads and PRCDs
- 10mA and 30mA Portable RCD lead testing options
- Substitute and Mains powered leakage testing
- Protective outer casing with front cover and toughened glass
PAT120 | PAT150 | PAT150R | |
---|---|---|---|
Earth Bond Continuity Test | ✔ | ✔ | ✔ |
Insulation Test (250V, 500V) | ✔ | ✔ | ✔ |
Substitute Leakage Test | ✔ | ✔ | ✔ |
Earth Leakage Test | ✔ | ✔ | |
Touch Current Test | ✔ | ✔ | |
Portable RCD Testing | ✔ | ✔ | |
Polarity Testing | ✔ | ✔ | |
Live Circuit Measurement | ✔ | ✔ | |
PASS/FAIL Indication | ✔ | ✔ | ✔ |
Battery Operated | ✔ | ✔ | ✔ |
Rechargeable | ✔ |
Environmental Conditions
- Operating ambient: 20°C
- Humidity: Nominal humidity
Continuity Test
- Test voltage: Compliance Voltage: +4V dc, –0 % /+10 % (open circuit)
- Test current: Bi-directional +200mA, -0% + 50mA (into 2Ω load)
- Continuity accuracy: Resistance: ± 5% ± 3 digits (0 to 19.99 Ω)
- Resistance resolution: 10 mΩ
- Display range: 0.01 to 19.99Ω
- Continuity test nulling: up to 9.99 Ω
- Test time: User selectable from 2 sec to 20 sec or selected during test to 180sec
Insulation Test
- Insulation test: 250V dc –0 % /+25 % open circuit, 500V dc –0 % /+25 % open circuit, ≥ 500V 0% dc across 0.5 MΩ load
- Short circuit/charge current: < 2mA dc
- Insulation accuracy: ±3% ±10 digits (0 to 19.99 MΩ)
- Resolution: 0.01 MΩ
- Display range: 0.10 MΩ to 99.99 MΩ
- Test duration: User selectable from 2 sec to 20 sec or selected during test to 180sec
Substitute Leakage Test
- Leakage current: Accuracy ± 5% ± 3 digits
- Test frequency: Nominal mains frequency 50Hz
- Test voltage: < 50V ac
- Resolution: 0.01mA
- Display range: 0.10 to 19.99mA
- Test duration: User selectable from 2 sec to 5 seconds
- Reading corrected to 230V ac.
Touch Current Test
- Test voltage: Nominal mains 230 V ac
- Test frequency: Nominal mains 50 Hz
- Test accuracy: ± 5% ± 3 digits
- Resolution: 0.01 mA
- Display range: 0.10 to 3.99 mA
- Test duration: User selectable from 2 sec to 5 sec
SELV Device Test
- Test voltage: 0 to 300 V ac
- Measurement accuracy: ± 3% ± 3 digits
- Resolution: 0.1 V ac
- Display range: 0.1 to 300 V ac
Extension Lead Test
Test includes Insulation and Bond tests.
- Test voltage: 5V
- Polarity: Lead OK, Live/neutral shorted, Live/neutral reversed, Live/neutral open circuit
Portable RCD Test
- Test voltage: Nominal mains 230 V
- Test frequency: 50Hz
- Test current accuracy: +2% to +8% (1 x I, 5 x I)
- Trip time accuracy: ±1% ± 1ms
- Trip time resolution: 0.01ms
- Display range: 0 to 200ms (1 x I), 0 to 40ms (5 x I)
Mains Supply Test
- Frequency measurement range: 50 Hz
- Test voltage: 40 to 300V ac
- Accuracy: ± 3% ± 3 digits
- Resolution: 0.1Vac
- Display range: 40 to 300V ac
Circuit Test
Carried out automatically, not available to user.
- Test voltage: 5V
- Test frequency: Nominal Mains 50 Hz
- Test current: < 100mA short circuit
Safety
- Instrument designed to IEC 61010-1: 2012
- Test leads designed to IEC 61010-031: 2005
- 300 volts to Earth Category II
- Mains fuse protection to 250 volts rms ac
EMC
- Design to meet IEC 61326-1: 2006 and IEC 61326-2-2: 2005.
Environmental
- Operating temperature range: 0°C to +40°C
- Storage temperature range: -20°C to +60°C
- Humidity: 90%RH @ +10°C +30°C, 75%RH @ +30°C to +40°C
- Maximum altitude: 2,000m to full safety spec.
- IP rating: IP40 (with front cover closed)
General
- Battery: Supply voltage, 12 Vdc (Alkaline AA LR6), 9.6 Vdc (NiMH AA LR6)
- Weight (PAT150 Only): 1300g
- Weight (Shipping): 2795g / 2975g for PAT150R
- Dimensions: 203 x 148 x 78mm
- Megger Part Number: 1003-064 / 1003-428 (rechargable model)
The Megger PAT150R Rechargeable PAT Tester comes with:
- Megger PAT150R (1003-428)
- Continuity/earth bond test lead Probe & Croc Clip
- Extension Lead Adaptor
- AC Charger Adaptor for Megger PAT150R only
- Mains Supply Cord
- SELV/mains voltage test lead Red
- Calibration certificate
- 8 x AA Batteries, 8 x rechargeable batteries for Megger PAT150R
- Instructions
- Carry Case
The Megger PAT150R PAT Tester is available in a range of kits:
Kit A | Kit B | Kit C | |
---|---|---|---|
Megger PAT150R PAT Tester | ✔ | ✔ | ✔ |
SimplyPATs Version 7 Manual Software | ✔ | ||
2 x 500 Pass Labels | ✔ | ✔ | ✔ |
200 Fail Labels | ✔ | ✔ | ✔ |
250 PassWrap Labels | ✔ | ✔ | ✔ |
PAT Register Book | ✔ | ✔ | ✔ |
PAT Certificate Pad | ✔ | ✔ | ✔ |
IEC Cloverleaf Adaptor | ✔ | ✔ | |
IEC Adaptor Kit | ✔ | ||
110V Appliance Adaptor | ✔ | ✔ | |
110V Extension Lead Adaptor | ✔ | ✔ | |
Microwave Leakage Detector | ✔ | ✔ | |
150 Microwave Emission Labels | ✔ | ✔ | |
Megger MST210 Socket Tester | ✔ | ✔ | ✔ |