COVID-19: Open for business - Click for more info.

FREE DELIVERY ON ORDERS OVER £150,
WITH NEXT-DAY OPTIONS ALSO AVAILABLE

Martindale HPAT400 Kit A

  • Includes a socket tester and microwave leakage detector
  • Martindale HPAT400 PAC Checker, ideal for office environments
  • Full set of PAT labels for appliances, leads and microwave leakage

£299.00 EXC. VAT

IN STOCK

Description

Please note that there may be delays on delivery of this product. For more information please 0113 248 9966.

Martindale HPAT400 PAT Tester Kit A is based around the Martindale HPAT400 PAC Checker, a useful instrument that provides clear PASS/FAIL indications for appliances and leads in domestic and office environments. Kit A includes accessories such as PAT labels, a socket tester, a microwave leakage detector and paper records.

The Martindale HPAT400 PAC Checker has automatic test sequences for Class I appliances, Class II appliances and power leads. All the user needs to do is correctly connect the tester and then select the appropriate test button to initiate a test sequence including an earth bond test, insulation test, leakage current test and/or polarity check.

An overall PASS/FAIL indication is displayed on the Martindale HPAT400’s digital screen alongside PASS/FAIL indications for each individual test.

Martindale HPAT400 Kit A Includes: 

  • Martindale HPAT400 PAC Checker (complete with Earth Bond Lead & Crocodile Clip, Mains Lead, 230V Extension Lead Adaptor, HPAT400 Instruction Manual, 6 x Rechargeable Batteries and Carry Case).
  • Microwave Leakage Detector
  • 50 Microwave Emission Labels
  • PAT Certificate Pad
  • PAT Register Book w/ Frequency of Inspection
  • IEC Clover Leaf Adaptor
  • Martindale CP501 Socket Tester
  • 1000 Pass Labels
  • 200 Fail Labels
  • 250 PassWrap Cable Labels
  Kit A Kit B Kit C Kit D
Martindale HPAT400 PAC Checker
Microwave Leakage Detector    
50 Microwave Emissions Labels    
PAT Certificate Pad    
PAT Register Book w/ Frequency of Inspection
IEC Clover Leaf Adaptor  
Martindale CP501 Check Plug  
1000 Pass Labels
200 Fail Labels
250 PassWrap Cable Labels
250 Tuff Tag Cable Labels    
Earth Bond Test Lead
Mains Lead
230V Extension Lead Adaptor
110V Appliance Adaptor    
110V Extension Lead Adaptor    
Rechargeable Batteries
HPAT400 Carry Case
Portable Appliance Tester Kit Carry Case  

Specification

EARTH CONTINUITY

  • Test voltage: 4V DC (into open circuit) Test current: 200mA DC (into short circuit)
  • Accuracy: ± 0.03Ω
  • Pass limits: Lead ≤ 0.20 Ω = PASS; Class I ≤ 0.20 Ω = PASS

INSULATION

  • Fixed voltage: >500V DC at 1mA (< 625V DC into open circuit)
  • Test current: 1.5mA (into short circuit)
  • Accuracy: ± 0.1MΩ
  • Pass limits: Lead: ≥ 1.0 MΩ; Class I: ≥ 1.0 MΩ; Class II: ≥ 2.0 MΩ

FUSE CHECK

  • Test voltage: 4V DC (into open circuit)
  • Test current: 200mA DC (into short circuit)
  • Pass level: >2mA

GENERAL

  • Overload protection: 300V AC/DC

Supplied Accessories

  • Martindale HPAT400 PAT Tester (complete with Earth Bond Lead & Crocodile Clip, Mains Lead, 230V Extension Lead Adaptor, HPAT400 Instruction Manual, 6 x Rechargeable Batteries and Carry Case).
  • Microwave Leakage Detector
  • 50 Microwave Emission Labels
  • PAT Certificate Pad
  • PAT Register Book w/ Frequency of Inspection
  • IEC Clover Leaf Adaptor
  • Martindale CP501 Socket Tester
  • 1000 Pass Labels
  • 200 Fail Labels
  • 250 PassWrap Cable Labels

Please note that there may be delays on delivery of this product. For more information please 0113 248 9966.

Martindale HPAT400 PAT Tester Kit A is based around the Martindale HPAT400 PAC Checker, a useful instrument that provides clear PASS/FAIL indications for appliances and leads in domestic and office environments. Kit A includes accessories such as PAT labels, a socket tester, a microwave leakage detector and paper records.

The Martindale HPAT400 PAC Checker has automatic test sequences for Class I appliances, Class II appliances and power leads. All the user needs to do is correctly connect the tester and then select the appropriate test button to initiate a test sequence including an earth bond test, insulation test, leakage current test and/or polarity check.

An overall PASS/FAIL indication is displayed on the Martindale HPAT400’s digital screen alongside PASS/FAIL indications for each individual test.

Martindale HPAT400 Kit A Includes: 

  • Martindale HPAT400 PAC Checker (complete with Earth Bond Lead & Crocodile Clip, Mains Lead, 230V Extension Lead Adaptor, HPAT400 Instruction Manual, 6 x Rechargeable Batteries and Carry Case).
  • Microwave Leakage Detector
  • 50 Microwave Emission Labels
  • PAT Certificate Pad
  • PAT Register Book w/ Frequency of Inspection
  • IEC Clover Leaf Adaptor
  • Martindale CP501 Socket Tester
  • 1000 Pass Labels
  • 200 Fail Labels
  • 250 PassWrap Cable Labels
  Kit A Kit B Kit C Kit D
Martindale HPAT400 PAC Checker
Microwave Leakage Detector    
50 Microwave Emissions Labels    
PAT Certificate Pad    
PAT Register Book w/ Frequency of Inspection
IEC Clover Leaf Adaptor  
Martindale CP501 Check Plug  
1000 Pass Labels
200 Fail Labels
250 PassWrap Cable Labels
250 Tuff Tag Cable Labels    
Earth Bond Test Lead
Mains Lead
230V Extension Lead Adaptor
110V Appliance Adaptor    
110V Extension Lead Adaptor    
Rechargeable Batteries
HPAT400 Carry Case
Portable Appliance Tester Kit Carry Case  

EARTH CONTINUITY

  • Test voltage: 4V DC (into open circuit) Test current: 200mA DC (into short circuit)
  • Accuracy: ± 0.03Ω
  • Pass limits: Lead ≤ 0.20 Ω = PASS; Class I ≤ 0.20 Ω = PASS

INSULATION

  • Fixed voltage: >500V DC at 1mA (< 625V DC into open circuit)
  • Test current: 1.5mA (into short circuit)
  • Accuracy: ± 0.1MΩ
  • Pass limits: Lead: ≥ 1.0 MΩ; Class I: ≥ 1.0 MΩ; Class II: ≥ 2.0 MΩ

FUSE CHECK

  • Test voltage: 4V DC (into open circuit)
  • Test current: 200mA DC (into short circuit)
  • Pass level: >2mA

GENERAL

  • Overload protection: 300V AC/DC
  • Martindale HPAT400 PAT Tester (complete with Earth Bond Lead & Crocodile Clip, Mains Lead, 230V Extension Lead Adaptor, HPAT400 Instruction Manual, 6 x Rechargeable Batteries and Carry Case).
  • Microwave Leakage Detector
  • 50 Microwave Emission Labels
  • PAT Certificate Pad
  • PAT Register Book w/ Frequency of Inspection
  • IEC Clover Leaf Adaptor
  • Martindale CP501 Socket Tester
  • 1000 Pass Labels
  • 200 Fail Labels
  • 250 PassWrap Cable Labels